Parameter Min Typ Max Units
 Input Voltage Range 9.0 24.0 36.0 VDC
18.0 48.0 75.0
 Output Accuracy   ±1.0 ±3.0 %
 Line Regulation   +VOUT   ±0.2 ±0.5 %
  -VOUT   ±0.5 ±1.0
 Load Regulation   +VOUT   ±0.5 ±1.0 %
  -VOUT   ±0.5 ±1.5
 Short Circuit Protection Continuous (Autorecovery)
 Isolation Voltage 1,500     VDC
 Operating Temp Range -40   +85 °C
 MTBF 1.0     MHrs
 Case Size 1.0 x 1.0 x 0.461 In
25.4 x 25.4 x 11.7 mm
         
Model No. Input Output V Output I
 MI1024S-03ERU-xxx 24 VDC 3.3 VDC 2,400 mA
 MI1024S-05ERU-xxx 24 VDC 5.0 VDC 2,000 mA
 MI1024S-09ERU-xxx 24 VDC 9.0 VDC 1,111 mA
 MI1024S-12ERU-xxx 24 VDC 12 VDC 833 mA
 MI1024S-15ERU-xxx 24 VDC 15 VDC 667 mA
 MI1024S-24ERU-xxx 24 VDC 24 VDC 416 mA
 MI1024D-05ERU-xxx 24 VDC ±5 VDC ±1,000 mA
 MI1024D-09ERU-xxx 24 VDC ±9.0 VDC ±555 mA
 MI1024D-12ERU-xxx 24 VDC ±12 VDC ±416 mA
 MI1024D-15ERU-xxx 24 VDC ±15 VDC ±333 mA
 MI1024D-24ERU-xxx 24 VDC ±24 VDC ±208 mA

 MI1048S-03ERU-xxx 48 VDC 3.3 VDC 2,400 mA
 MI1048S-05ERU-xxx 48 VDC 5.0 VDC 2,000 mA
 MI1048S-12ERU-xxx 48 VDC 12 VDC 833 mA
 MI1048S-15ERU-xxx 48 VDC 15 VDC 667 mA
 MI1048S-24ERU-xxx 48 VDC 24 VDC 416 mA
 MI1048D-05ERU-xxx 48 VDC ±5 VDC ±1,000 mA
 MI1048D-12ERU-xxx 48 VDC ±12 VDC ±416 mA
 MI1048D-15ERU-xxx 48 VDC ±15 VDC ±333 mA
 MI1048D-24ERU-xxx 48 VDC ±24 VDC ±208 mA
* For Chassis Mount Adapter:
Add "A2S" To The Model Number (i.e. MI1024S-12ERU-A2S)
* For DIN Rail Adapter:
Add "A4S" To The Model Number (i.e. MI1024S-12ERU-A4S)
       
MI1000ERU Downloads: (Click on the picture)
         
Datasheet   E-Book
On-Line
  E-Book
Download
      Filter Modules

Additional Tech Info: (Click on the picture)
    MI1000ERU   A2S Adapter   A4S Adapter    
         
Safety C of C   3D-CAD   3D-CAD   3D-CAD    

Similar Products: (Click on the picture)
MA1000RU   MB1000ERU   MA1000RW        
           
10W DIP
4:1 1.5k Iso
  10W 1x2"
4:1 1.5K Iso
  10W DIP
2:1 1.5k Iso
       

Many other DC/DC's in this power range are available. contact the factory for more info.