Parameter Min Typ Max Units
 Input Voltage Range 9.0 12.0 18.0 VDC
18.0 24.0 36.0
36.0 48.0 75.0
 Output Accuracy     ±1.0 %
 Line Regulation   ±0.3 ±0.5 %
 Load Regulation   ±0.5 ±1.0 %
 Short Circuit Protection Continuous (Autorecovery)
 Isolation Voltage 4,200     VAC rms
 Operating Temp Range -40   +75 °C
 MTBF 1.0     MHrs
 Case Size 2.0 x 1.0 x 0.47 In
50.8 x 25.4 x 12.0 mm
 Safety Standards EN 60601, UL 60601
EN 60950, UL 60950
         
Model No. Input Output V Output I
 MB1012MS-05HI 12 VDC 5.0 VDC 2,000 mA
 MB1012MS-051HI 12 VDC 5.1 VDC 830 mA
 MB1012MS-12HI 12 VDC 12 VDC 670 mA
 MB1012MD-12HI 12 VDC ±12 VDC ±416 mA
 MB1012MD-15HI 12 VDC ±15 VDC ±333 mA

 MB1024MS-05HI 24 VDC 5.0 VDC 2,000 mA
 MB1024MS-051HI 24 VDC 5.1 VDC 830 mA
 MB1024MS-12HI 24 VDC 12 VDC 670 mA
 MB1024MD-12HI 24 VDC ±12 VDC ±416 mA
 MB1024MD-15HI 24 VDC ±15 VDC ±333 mA

 MB1048MS-05HI 48 VDC 5.0 VDC 2,000 mA
 MB1048MS-051HI 48 VDC 5.1 VDC 830 mA
 MB1048MS-12HI 48 VDC 12 VDC 670 mA
 MB1048MD-12HI 48 VDC ±12 VDC ±416 mA
 MB1048MD-15HI 48 VDC ±15 VDC ±333 mA
       
  

Click on the photo to download the full datasheet

 


Click on the photo to download the Safety C of C (EN 60950)

 


Click on the photo to download the Safety C of C (EN 60601)