Parameter Min Typ Max Units
 Input Voltage Range 90   305 VAC
 Input Type Universal
 Input Frequency 47   63 Hz
 Inrush Current, 230 VAC   75   APk
 Power Factor Correction 0.98 @ 115 VAC
0.95 @ 230 VAC
0.93 @ 264 VAC
 Output Current Accuracy   ±5.0   %
 Line Regulation   ±1.0   %
 Hold-Up Time, 115 VAC 12     mSec
 Efficiency   94   %
 Dimming Control Resistive, Analog, PWM
 Isolation Voltage 3,750     VAC
 Operating Temp Range -40   +70 °C
 Life Expectency 50     kHrs
 MTBF 220     kHrs
 Case Size 9.56 x 2.64 x 1.57 In
243.0 x 67.0 x 40.0 mm
 Safety Standards UL 8750, Meets EN 61347, GB 19510
 EMI Standards EN 55015; EN 6100-3-2,-3; GB 17743
 EMS Standards EN 61547;EN 61000-4-2,-3,-4,-5,-6,-8,-11
 Surge 10 kV (L/N - FG),5 kV (L-N)/1.2 x 50 ┬ÁS
 Ingress Rating IP65, IP67
         
Model No. Output I I Adj Range Output V
 LDC-240-0700(*) 700 mA 420 - 700 mA 200 - 400 VDC
 LDC-240-1050(*) 1,050 mA 630 - 1,050 mA 134 - 267 VDC
 LDC-240-1400(*) 1,400 mA 840 - 1,400 mA 100 - 200 VDC
 LDC-240-4200(*) 4,200 mA 2,520 - 4,200 mA 27 - 56 VDC
 LDC-240-4900(*) 4,900 mA 2,940 - 4,900 mA 24 - 49 VDC
 LDC-240-5600(*) 5,600 mA 3,360 - 5,600 mA 21 - 42 VDC
 LDC-240-7000(*) 7,000 mA 4,200 - 7,000 mA 18 - 35 VDC
* Models with (A) are IP65 & IOUT is adjusted by an internal resister
* Models with (B) are IP67 & IOUT is adjusted by an external resister, PWM signal, etc
       
  

Click on the photo to download the full datasheet

 


Click on the photo to download the Safety C of C

 

  

Click on the photo to download the "Driving LEDs" App Note