Parameter Min Typ Max Units
 Input Voltage Range 90   305 VAC
 Input Type Universal
 Input Frequency 47   63 Hz
 Inrush Current, 230 VAC   75   APk
 Power Factor Correction 0.98 @ 115 VAC
0.95 @ 230 VAC
0.93 @ 264 VAC
 Output Current Accuracy   ±5.0   %
 Line Regulation   ±1.0   %
 Hold-Up Time, 115 VAC 12     mSec
 Efficiency   92   %
 Dimming Control Resistive, Analog, PWM
 Isolation Voltage 3,750     VAC
 Operating Temp Range -40   +70 °C
 Life Expectency 50     kHrs
 MTBF 220     kHrs
 Case Size 8.62 x 2.64 x 1.57 In
219.0 x 67.0 x 40.0 mm
 Safety Standards UL 8750, Meets EN 61347, GB 19510
 EMI Standards EN 55015; EN 6100-3-2,-3; GB 17743
 EMS Standards EN 61547;EN 61000-4-2,-3,-4,-5,-6,-8,-11
 Surge 10 kV (L/N - FG),5 kV (L-N)/1.2 x 50 ┬ÁS
 Ingress Rating IP65, IP67
         
Model No. Output I I Adj Range Output V
 LDC-185-0500(*) 500 mA 300 - 500 mA 200 - 400 VDC
 LDC-185-0700(*) 700 mA 360 - 700 mA 143 - 286 VDC
 LDC-185-1050(*) 1,050 mA 600 - 1,050 mA 95 - 190 VDC
 LDC-185-1400(*) 1,400 mA 750 - 1,400 mA 71 - 143 VDC
 LDC-185-3150(*) 1,050 mA 1,650 - 1,150 mA 32 - 58 VDC
 LDC-185-3850(*) 3,850 mA 2,000 - 3,850 mA 32 - 49 VDC
 LDC-185-4200(*) 4,200 mA 2,200 - 4,200 mA 27 - 42 VDC
 LDC-185-5200(*) 5,250 mA 2,750 - 5,250 mA 25 - 35 VDC
* Models with (A) are IP65 & IOUT is adjusted by an internal resister
* Models with (B) are IP67 & IOUT is adjusted by an external resister, PWM signal, etc
       
  

Click on the photo to download the full datasheet

 


Click on the photo to download the Safety C of C

 

  

Click on the photo to download the "Driving LEDs" App Note