Parameter Min Typ Max Units
 Input Voltage Range 90   264 VAC
 Input Type Universal
 Input Frequency 47   63 Hz
 Power Factor Correction Meets EN 61000-3-2 Class D
 Inrush Current 230 VAC     70.0 APk
 Output Regulation   ±1.0   %
 Hold-Up Time, 115 VAC 16     mSec
 Isolation Voltage 3,000     VAC
 Operating Temp Range 0   +50 °C
 MTBF 100     kHrs
 Package Type U-Channel
 Case Size 8.00 x 6.00 x 1.60 In
  203.20 x 127.00 x 40.64 mm
 Package Type End Fan "E" Models
 Case Size 9.00 x 6.00 x 1.60 In
  228.60 x 127.00 x 40.64 mm
 Package Type Top Fan "F" Models
 Case Size 8.00 x 6.00 x 2.20 In
  203.20 x 127.00 x 55.88 mm
 Safety Standards EN 60950, UL 60950
 EMI/EMC Standards EN 55022, EN 61000-4
         
Model No. Output V Output I*
 MPU-600CD-0512yyz 5.0 VDC 50.00A
12 VDC 33.00A
 MPU-600CD-0524yyz 5.0 VDC 50.00A
24 VDC 16.67A
 MPU-600CD-1224yyz 12 VDC 33.33A
48 VDC 16.67A
* With 25 CFM
For mechanical configurations: "y" = T for terminal blocks
  "y" = A for molex connectors
  "z" = blank for u-channel
  "z" = E for End Fan
  "z" = F for Top Fan
     
MPU-600CD Downloads: (Click on the picture)
           
Datasheet   E-Book
On-Line
  E-Book
Download
       

Additional Tech Info: (Click on the picture)
         
Safety C of C   3D-CAD
U Chan.
  3D-CAD
End Fan
  3D-CAD
Top Fan
   

Similar Products: (Click on the picture)
MPU-600CS   MPU-500SE   MPU-400D        
           
600W Sing
U Channel
  500W
End Fan Case
  400W Dual
U Channel
       

Many other AC/DC products are available (from 1W to 600W). contact the factory for more info.