Parameter | Min | Typ | Max | Units | |
Input Voltage Range | 90 | 132 | VAC | ||
180 | 264 | ||||
Input Type | Autoranging | ||||
Input Frequency | 47 | 63 | Hz | ||
Power Factor Correction | Meets EN 61000-3-2 | ||||
Inrush Current | 115 VAC | 35.0 | APk | ||
230 VAC | 70.0 | ||||
Output Regulation | ±5.0 | % | |||
Hold-Up Time, 110 VAC | 20 | mSec | |||
Isolation Voltage | 3,000 | VAC | |||
Operating Temp Range | 0 | +70 | °C | ||
MTBF | 100 | kHrs | |||
Package Type | U-Channel Models | ||||
Case Size | 6.00 x 4.00 x 1.50 In | ||||
152.40 x 101.60 x 38.10 mm | |||||
Package Type | End Fan "E" Models | ||||
Case Size | 7.00 x 4.00 x 1.60 In | ||||
175.28 x 101.60 x 40.64 mm | |||||
Package Type | Top Fan "F" Models | ||||
Case Size | 6.00 x 4.00 x 2.00 In | ||||
152.40 x 101.60 x 50.80 mm | |||||
Safety Standards | EN 60950, UL 60950 | ||||
EMI/EMC Standards | EN 55022, EN 61000-4 | ||||
Model No. | Output V | Output I* |
MPU-300D-0512yz | 5 VDC | 30.00A |
12 VDC | 16.67A | |
MPU-300D-0524yz | 5 VDC | 30.00A |
24 VDC | 8.33A | |
MPU-300D-0548yz | 5 VDC | 30.00A |
48 VDC | 4.16A | |
MPU-300D-1224yz | 12 VDC | 16.67A |
24 VDC | 8.33A | |
* With 18 CFM | ||
For mechanical configurations | "y" = T for terminal blocks | |
"y" = A for molex connectors | ||
"z" = C for Cover | ||
"z" = E for End Fan | ||
"z" = F for Top Fan | ||
"z" = blank for u-channel | ||