Parameter Min Typ Max Units
 Input Voltage Range 90   264 VAC
120   370 VDC
 Input Type Universal
 Input Frequency 47   63 Hz
 Inrush Current 115 VAC     35.0 APk
230 VAC     70.0
 Line Regulation   ±1.0   %
 Load Regulation   ±1.2   %
 Hold-Up Time, 115 VAC 8     mSec
 Isolation Voltage 3,000     VAC
 Operating Temp Range -30   +70 °C
 MTBF 160     kHrs
 Case Size 5.0 x 3.0 x 1.52 In
127.00 x 76.20 x 38.50 mm
 Package Type Open Frame
 Safety Standards EN 60950, UL 60950
 EMI/EMC Standards EN 55022, EN 61000-4
         
Model No. Output V Output I
 MPO-500S-12T 12 VDC 41.50 A *
 MPO-500S-24T 24 VDC 20.80 A *
 MPO-500S-48T 48 VDC 10.41 A *
* With 30 CFM Airflow
     
MPO-500S Downloads: (Click on the picture)
           
Datasheet   E-Book
On-Line
  E-Book
Download
       

Additional Tech Info: (Click on the picture)
             
Safety C of C   3D-CAD            

Similar Products: (Click on the picture)
MPU-400CS   MPU-600CS   MPU-300S        
           
400W
U Channel
  600W
U Channel
  300W
U Channel
       