Parameter Min Typ Max Units
 Input Voltage Range 165   264 VAC
180   370 VDC
 Input Frequency 47   63 Hz
 Inrush Current 230 VAC   50.0   APk
 Line Regulation   ±0.5   %
 Load Regulation   ±2.0   %
 Hold-Up Time, 230 VAC   60   mSec
 Isolation Voltage 3,000     VAC
 Operating Temp Range -40   +70 °C
 MTBF 250     kHrs
 Case Size 4.56 x 1.77 x 4.45 In
115.8 x 45.0 x 113.0 mm
 Package Type DIN Rail Mount
 EMI/EMC Standards EN 55022, EN 61000-4
         
Model No. Output V Output I
 MDR-72S-24 24.0 VDC 3.0 A
     
  

Click on the photo to download the full datasheet