www.micropowerdirect.comww.micropowerdirect.com.micropowerdirect.com
Model Selection Guide w www
Input (Supply) Output 1 Output 2 Fuse
Model Rating
Number Voltage (VDC) Current (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA) Slow-Blow
Nom. Range Full Load No Load Min. Nom. Max. Max Min Min. Nom. Max. Max Min (mA)
IG220-12 12 10.80 - 13.20 280 20 19.60 20.0 20.40 100.0 10.0 -3.70 -4.00 -4.10 -100.0 -10.0 500
IG220-15 15 13.50 - 16.50 193 16 17.70 18.0 18.45 100.0 10.0 -2.90 -3.00 -3.20 -100.0 -10.0 400
IG220-24 24 21.60 - 26.40 125 13 19.50 20.0 20.50 100.0 10.0 -3.70 -4.00 -4.30 -100.0 -10.0 250
Notes: Derating Curve
1. Line regulation is measured for an input voltage change of ±10%.
2. Load regulation is measured from 10% load to full load.
3. When measuring output ripple & noise, it is recommended that an exter-
nal capacitor (1 µF to 10 µF) be placed from each output to common.
The typical noise specifi ed for the IG220-12 is 100 mV P - P.
4. The unit will meet the radiated and conducted EMI specifi cations
with the addition of external components as shown in the con-
nection diagram on page 3.
5. Operation at no-load will not damage these units. However, they
may not meet all specifi cations.
6. It is recommended that a fuse be used on the input of a power
supply for protection. See the Model Selection table above for
the correct rating.



Effi ciency vs Input Voltage 12 VDC Input Effi ciency vs Output Load 12 VDC Input


















Effi ciency vs Input Voltage 15 VDC Input Effi ciency vs Output Load 15 VDC Input

















Effi ciency vs Input Voltage 24 VDC Input Effi ciency vs Output Load 24 VDC Input


















MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com