Model Selection Guide www.micropowerdirect.com
Input Output Output
Load Fuse Rating
Model Effi ciency Capacitive
Number Voltage (VDC) Current (mA) Voltage Current Current Regulation (%, Typ) Load Slow-Blow
(VDC) (mA, Max) (mA, Min) (%, Max) (µF, Max) (mA)
Nominal Range Full-Load No-Load
ML205S-03 5 4.50 - 5.50 471 60 3.3 500 10.0 11 73 47 1,000
ML205S-05 5 4.50 - 5.50 548 60 5.0 400 8.0 11 78 47 1,000
ML205S-12 5 4.50 - 5.50 514 60 12.0 165 3.0 11 78 10 1,000
ML205D-05 5 4.50 - 5.50 541 60 ±5.0 ±200 ±4.0 10 74 10 1,000
ML205D-12 5 4.50 - 5.50 524 60 ±12.0 ±83 ±1.5 7 78 4.7 1,000
ML205D-15 5 4.50 - 5.50 521 60 ±15.0 ±66 ±1.0 7 78 4.7 1,000
ML212S-03 12 10.8 - 13.2 191 30 3.3 500 10.0 8 74 47 500
ML212S-05 12 10.8 - 13.2 222 30 5.0 400 8.0 8 76 47 500
ML212S-12 12 10.8 - 13.2 209 30 12.0 165 3.0 5 79 10 500
ML212D-12 12 10.8 - 13.2 208 30 ±12.0 ±83 ±1.5 5 78 4.7 500
ML212D-15 12 10.8 - 13.2 206 30 ±15.0 ±66 ±1.0 5 79 4.7 500
ML224S-03 24 21.6 - 26.4 96 15 3.3 500 10.0 8 72 47 250
ML224S-05 24 21.6 - 26.4 111 15 5.0 400 8.0 8 78 47 250
ML224S-12 24 21.6 - 26.4 105 15 12.0 165 3.0 5 77 10 250
ML224D-12 24 21.6 - 26.4 105 15 ±12.0 ±83 ±1.5 5 78 4.7 250
ML224D-15 24 21.6 - 26.4 104 15 ±15.0 ±66 ±1.0 5 78 4.7 250

Notes:
1. The specifi ed maximum capacitive load is for each output. Derating Curve
2. Load regulation is measured for an output change of 20% to 100%.
3. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor
be placed from each output to the common pin. For noise sensitive applications, the use of 3.3
µF capacitors will reduce the output ripple.
4. Operation at no-load will not damage these units. However, they may not meet all specifi cations.
5. The converter should be connected to a low ac-impedance source. An input source with a
highly inductive impedance may affect the stability of the converter. In applications where the
converter output loading is high and input power is supplied over long lines, it may be necessary
to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted
close to the converter. For 5V input units a 2.2 µF is recommended; a 1.0 µF for 12V input
units; and for 24V input models, a 0.47 µF.
6. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this,
connect the load across the positive (+Vout) and negative (-Vout) outputs and fl oat the output
common.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the
table above for the correct rating.

Refl ow Solder Settings









The ML200x series is designed to meet the IPC/
JEDEC standard J-STD-020D for refl ow solder-
ing. The recommended refl ow settings are a peak
temperature of 245 °C for a maximum period
(TPK) of 10S and a time above liquidous (TL) of
<60 seconds at 217 °C, as illustrated above. For
more information, please contact the factory.