Page 2 - MPD ML200SEI Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Load Fuse Rating
Model Regulation Effi ciency
Number Voltage (VDC) Current (mA) Voltage Current Current (%, Typ) Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) % Typ. (mA)
ML205S-05EI 5 4.50 - 5.50 506 30 5.0 400.0 40.0 12.0 79 1,000
ML205S-09EI 5 4.50 - 5.50 489 30 9.0 222.0 22.0 9.0 82 1,000
ML205S-12EI 5 4.50 - 5.50 489 30 12.0 167.0 17.0 8.0 82 1,000
ML205S-15EI 5 4.50 - 5.50 482 30 15.0 133.0 13.0 7.0 83 1,000
ML212S-05EI 12 10.8 - 13.2 211 25 5.0 400.0 40.0 12.0 79 500
ML212S-12EI 12 10.8 - 13.2 203 25 12.0 167.0 17.0 8.0 82 500
ML212S-15EI 12 10.8 - 13.2 201 25 15.0 133.0 13.0 7.0 83 500
ML212S-24EI 12 10.8 - 13.2 198 25 24.0 83.0 8.0 6.0 84 500
ML215S-15EI 15 13.5 - 16.5 169 18 15.0 133.0 13.0 7.0 83 400
ML224S-05EI 24 21.6 - 26.4 105 15 5.0 400.0 40.0 12.0 79 250
ML224S-12EI 24 21.6 - 26.4 102 15 12.0 167.0 17.0 8.0 82 250
ML224S-15EI 24 21.6 - 26.4 100 15 15.0 133.0 13.0 7.0 83 250
ML224S-24EI 24 21.6 - 26.4 97 15 24.0 83.0 8.0 6.0 86 250
Notes:
1. Output load regulation is specifi ed for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that a 1 µF capacitor and a 10 µF capacitor be placed in Derating Curve
parallel from the +Vout pin to the -Vout pin.
3. It is recommended that the minimu output load should be at least 10%. Continuous operation below this level
could damage the unit.
4. These converters are specifi ed for operation without external components. However, in some applications the
addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection shown
below will typically meet EN 55022 Class B.










VIN C1 C2 L1 VOUT C3
5 VDC 4.7 µF/50V 6.8 µH 5 VDC 10 µF
12 VDC 4.7 µF/50V 6.8 µH 9 VDC 4.7 µF
15 VDC 4.7 µF/50V 6.8 µH 12 VDC 2.2 µF Pin Connections
24 VDC 4.7 µF/50V 1 nF/3 kV 6.8 µH 15 VDC 1.0 µF Pin Description Pin Description
24 VDC 0.47 µF Mechanical Dimensions
1-V 4-VOUT
IN
5. The recommended refl ow settings are a peak temperature of 245 °C for a 2+VIN 5+VOUT
maximum period (TPK) of 10S and a time above liquidous (TL) of <60 seconds at
217 °C. For more information, please contact the factory. 8NC
6. It is recommended that a fuse be used on the input of a power supply for NC = No Connection
protection. See the Model Selection table above for the correct rating.
Board Layout



















MicroPower Direct Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less! • Pin 1 is marked by a “dot” or indentation on the unit
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
   1   2