Model Selection Guide www.micropowerdirect.com
Input Output
Load Fuse Rating
Model Regulation Effi ciency Safety
Number Voltage (VDC) Current (mA) Voltage Current Current (%, Typ) (EN 6950) Slow-Blow
(VDC) (mA, Max) (mA, Min) (mA)
Nominal Range Full-Load No-Load % Typ.
ML103S-03E 3.3 2.97 - 3.63 433 25 3.3 303.0 30.0 18.0 69 No 1,000
ML103S-05E 3.3 2.97 - 3.63 409 25 5.0 200.0 20.0 12.0 74 Yes 1,000
ML103S-09E 3.3 2.97 - 3.63 388 25 9.0 111.0 12.0 8.0 78 No 1,000
ML103S-12E 3.3 2.97 - 3.63 378 25 12.0 84.0 9.0 7.0 80 No 1,000
ML103S-15E 3.3 2.97 - 3.63 378 25 15.0 67.0 7.0 6.0 80 No 1,000
ML103S-24E 3.3 2.97 - 3.63 378 25 24.0 42.0 4.0 5.0 80 No 1,000
ML105S-03E 5 4.50 - 5.50 277 20 3.3 303.0 30.0 18.0 72 Yes 500
ML105S-05E 5 4.50 - 5.50 250 20 5.0 200.0 20.0 12.0 80 Yes 500
ML105S-06E 5 4.50 - 5.50 250 20 9.0 167.0 17.0 10.0 80 Yes 500
ML105S-09E 5 4.50 - 5.50 250 20 9.0 111.0 12.0 8.0 80 Yes 500
ML105S-12E 5 4.50 - 5.50 250 20 12.0 84.0 9.0 7.0 80 Yes 500
ML105S-15E 5 4.50 - 5.50 250 20 15.0 67.0 7.0 6.0 80 Yes 500
ML105S-24E 5 4.50 - 5.50 250 20 24.0 42.0 4.0 5.0 80 Yes 500
ML112S-03E 12 10.8 - 13.2 116 15 3.3 303.0 30.0 18.0 72 Yes 200
ML112S-05E 12 10.8 - 13.2 104 15 5.0 200.0 20.0 12.0 80 Yes 200
ML112S-09E 12 10.8 - 13.2 104 15 9.0 111.0 12.0 8.0 80 Yes 200
ML112S-12E 12 10.8 - 13.2 104 15 12.0 84.0 9.0 7.0 80 Yes 200
ML112S-15E 12 10.8 - 13.2 104 15 15.0 67.0 7.0 6.0 80 Yes 200
ML112S-24E 12 10.8 - 13.2 104 15 24.0 42.0 4.0 5.0 80 Yes 200
ML115S-05E 15 13.5 - 16.5 83 10 5.0 200.0 20.0 12.0 80 No 200
ML115S-15E 15 13.5 - 16.5 83 10 15.0 67.0 7.0 6.0 80 No 200
ML124S-05E 24 21.6 - 26.4 52 7 5.0 200.0 20.0 12.0 80 Yes 100
ML124S-09E 24 21.6 - 26.4 52 7 9.0 110.0 11.0 8.0 80 Yes 100
ML124S-12E 24 21.6 - 26.4 52 7 12.0 84.0 9.0 7.0 80 No 100
ML124S-15E 24 21.6 - 26.4 52 7 15.0 67.0 7.0 6.0 80 Yes 100
ML124S-24E 24 21.6 - 26.4 52 7 24.0 42.0 4.0 5.0 80 Yes 100
Notes: Derating Curve
1. Output load regulation is specifi ed for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic
capacitor be placed from the +VOUT pin to the -VOUT pin.
3. The ML105S-24E & ML124-xxE models have momentary (1S) protection against
short circuit.
4. These converters are specifi ed for operation without external components. How-
ever, in some applications the addition of input/output capacitors will enhance
stability and reduce output ripple. The simple connection shown on page 3 will
typically meet EN 55022 Class B.
5. The recommended refl ow settings are a peak temperature of 245 °C for a
maximum period (TPK) of 10S and a time above liquidous (TL) of <60 seconds
at 217 °C. For more information, please contact the factory.
6. Operation at no load will not damage these units, however, they may not meet all
specifi cations. Operation below 10% load will cause the output voltage to rise.
7. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.


Characteristic Curves
Tolerance Envelope (Nominal Input), 3.3 VDC Output Models Tolerance Envelope (Nominal Input), All Other Models


























MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com