Page 2 - MPD ML100DE Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Load Fuse Rating
Model Regulation Effi ciency
Number Voltage (VDC) Current (mA) Voltage Current Current (%, Typ) Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) % Typ. (mA)
ML103D-05E 3.3 2.97 - 3.63 388 25 ±5.0 ±100.0 ±10.0 12.0 78 750
ML103D-12E 3.3 2.97 - 3.63 379 25 ±12.0 ±42.0 ±5.0 7.0 80 750
ML103D-15E 3.3 2.97 - 3.63 379 25 ±15.0 ±33.0 ±3.0 6.0 80 750
ML105D-05E 5.0 4.50 - 5.50 250 20 ±5.0 ±100.0 ±10.0 12.0 80 500
ML105D-09E 5.0 4.50 - 5.50 250 20 ±9.0 ±56.0 ±6.0 8.0 80 500
ML105D-12E 5.0 4.50 - 5.50 247 20 ±12.0 ±42.0 ±5.0 7.0 81 500
ML105D-15E 5.0 4.50 - 5.50 247 20 ±15.0 ±33.0 ±3.0 6.0 81 500
ML105D-24E 5.0 4.50 - 5.50 247 20 ±24.0 ±21.0 ±2.0 5.0 81 500
ML112D-05E 12 10.8 - 13.2 104 15 ±5.0 ±100.0 ±10.0 12.0 80 250
ML112D-09E 12 10.8 - 13.2 104 15 ±9.0 ±56.0 ±6.0 8.0 80 250
ML112D-12E 12 10.8 - 13.2 103 15 ±12.0 ±42.0 ±5.0 7.0 81 250
ML112D-15E 12 10.8 - 13.2 103 15 ±15.0 ±33.0 ±3.0 6.0 81 250
ML112D-24E 12 10.8 - 13.2 103 15 ±24.0 ±21.0 ±2.0 5.0 81 250
ML124D-05E 24 21.6 - 26.4 51 7 ±5.0 ±100.0 ±10.0 12.0 82 100
ML124D-09E 24 21.6 - 26.4 51 7 ±9.0 ±56.0 ±6.0 8.0 82 100
ML124D-12E 24 21.6 - 26.4 51 7 ±12.0 ±42.0 ±5.0 7.0 82 100
ML124D-15E 24 21.6 - 26.4 51 7 ±15.0 ±33.0 ±3.0 6.0 82 100
ML124D-24E 24 21.6 - 26.4 51 7 ±24.0 ±21.0 ±2.0 5.0 82 100
Notes: Derating Curve
1. Output load regulation is specifi ed for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that a 1 µF capacitor and a 10 µF capacitor be placed in parallel
from each output to common.
3. The short circuit protection for model ML105D-24E is momentary (>1S). All other models have continuous short
circuit protection
4. It is recommended that the minimum output load should be at least 10%. Operation below this level will not
damage the unit, but it may not meet all specifi cations.
5. These converters are specifi ed for operation without external components. However, in some applications the
addition of input/output capacitors will enhance stability and reduce output ripple. The simple connection shown
below will typically meet EN 55022 Class B.








VIN C1 L1 VOUT C2 C3
3.3 VDC 4.7 µF/50V 6.8 µH ±5 VDC 4.7 µF 4.7 µF Pin Connections
5.0 VDC 4.7 µF/50V 6.8 µH ±9 VDC 2.2 µF 2.2 µF
Pin Description Pin Description
12 VDC 4.7 µF/50V 6.8 µH ±12 VDC 1.0 µF 1.0 µF
1-V 5-VOUT
IN
24 VDC 4.7 µF/50V 6.8 µH ±15 VDC 1.0 µF 1.0 µF
2+VIN 7+VOUT
±24 VDC 0.47 µF 0.47 µF
4 Common 10 NC
Mechanical Dimensions
6. The recommended refl ow settings are a peak temperature of 245 °C for a NC = No Connection
maximum period (TPK) of 10S and a time above liquidous (TL) of <60 seconds at
217 °C. For more information, please contact the factory.
7. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Board Layout

















MicroPower Direct Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less! • Pin 1 is marked by a “dot” or indentation on the unit
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com