Page 2 - MPD MH600xRU Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output
Model Capacitive Effi ciency Fuse Rating
Load
Number Voltage (VDC) Current (mA) Voltage Current Current (µF Max) (%, Typ) Slow-Blow
(mA)
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min)
MH624S-03RU 24 9.0 - 36.0 262 30 3.3 1,450.0 218.0 330 76 1,500
MH624S-05RU 24 9.0 - 36.0 316 30 5.0 1200.0 180.0 330 79 1,500
MH624S-12RU 24 9.0 - 36.0 301 30 12.0 500.0 75.0 100 83 1,500
MH624S-15RU 24 9.0 - 36.0 301 30 15.0 400.0 60.0 100 83 1,500
MH624S-24RU 24 9.0 - 36.0 301 30 24.0 250.0 38.0 100 83 1,500
MH624D-05RU 24 9.0 - 36.0 301 30 ±5.0 ±600.0 ±90.0 100 82 1,500
MH624D-12RU 24 9.0 - 36.0 301 30 ±12.0 ±250.0 ±38.0 100 83 1,500
MH624D-15RU 24 9.0 - 36.0 301 30 ±15.0 ±200.0 ±30.0 100 83 1,500
MH648S-03RU 48 18.0 - 75.0 131 20 3.3 1,450.0 218.0 330 76 750
MH648S-05RU 48 18.0 - 75.0 158 20 5.0 1200.0 180.0 330 79 750
MH648S-12RU 48 18.0 - 75.0 151 20 12.0 500.0 75.0 100 83 750
MH648S-15RU 48 18.0 - 75.0 151 20 15.0 400.0 60.0 100 83 750
MH648S-24RU 48 18.0 - 75.0 151 20 24.0 250.0 38.0 100 83 750
MH648D-05RU 48 18.0 - 75.0 151 20 ±5.0 ±600.0 ±90.0 100 82 750
MH648D-12RU 48 18.0 - 75.0 151 20 ±12.0 ±250.0 ±38.0 100 83 750
MH648D-15RU 48 18.0 - 75.0 151 10 ±15.0 ±200.0 ±30.0 100 83 750
Notes: Remote On/Off
1. The specifi ed maximum capacitive load is for each output.
2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic
capacitor is connected from the +VOUT to the -VOUT pins. If the application is noise sensitive; Parameter Conditions Min. Typ. Max. Units
connecting a low ESR 3.3 µF capcitor should be used. This capacitor should be mounted Unit On 2.5 VDC - 50.0 VDC or Open Circuit
as close to the converter as possible.
3. Transient recovery is measured to within a 1% error band for a load step change Unit Off 0.7 VDC - 0.8 VDC or Short Circuit
of 25%.
4. Output overload protection is provided by a fold back current limiting circuit with Control Input Current, ON VCTRL = 5V 500 µA
auto-recovery. A long-term overload could damage the unit. Control Input Current, OFF VCTRL = 0V -500 µA
5. Operation at no load will not damage these units.
6. It is recommended that a fuse be used on the input of a power supply for protection. Control Common Referenced to -VIN (Pin 2)
See the Model Selection table above for the correct rating.
Standby Input Current 10.0 mA

Derating Curve
Mechanical Dimensions



















Pin Con nec tions
Pin Single Pin Dual
1 Remote On/Off 1 Remote On/Off
2-V 2-VIN
IN
6 No Connection 6 Common
N 8 No Connection 8 -VOUT
Notes:otes:
• All dimensions are typical in inches (mm)
• All dimensions are typical in inches (mm)
9+VOUT 9+VOUT
• • Tolerance x.xx = ±0.02 (±0.5)Tolerance x.xx = ±0.02 (±0.5)
11 -VOUT 11 Common
• Pin 1 is marked by a “dot” or indentation on
• Pin 1 is marked by a “dot” or indentation on the unit
16 +VIN 16 +VIN