Page 2 - MPD MH100S Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Capacitive Fuse
Model Load Effi ciency Rating
Voltage (VDC) Current (mA) Voltage Current Regulation Load
Number (%, Typ) Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (% Typ) (µF, Max) (mA)
MH103S-03 3.3 2.97 - 3.63 410 25 3.3 303.0 ±20 74 220 1,000
MH103S-05 3.3 2.97 - 3.63 394 25 5.0 200.0 ±10 77 220 1,000
MH103S-09 3.3 2.97 - 3.63 399 30 9.0 111.0 ±10 76 220 1,000
MH103S-12 3.3 2.97 - 3.63 485 45 12.0 100.0 ±10 75 220 1,000
MH103S-15 3.3 2.97 - 3.63 384 25 15.0 67.0 ±10 79 220 1,000
MH103S-18 3.3 2.97 - 3.63 399 35 18.0 56.0 ±10 76 220 1,000
MH103S-24 3.3 2.97 - 3.63 485 90 24.0 50.0 ±10 75 220 1,000
MH105S-03 5.0 4.5 - 5.5 256 16 3.3 303.0 ±20 78 220 750
MH105S-05 5.0 4.5 - 5.5 253 15 5.0 200.0 ±10 79 220 750
MH105S-09 5.0 4.5 - 5.5 253 25 9.0 111.0 ±10 79 220 750
MH105S-12 5.0 4.5 - 5.5 296 25 12.0 100.0 ±10 81 220 750
MH105S-15 5.0 4.5 - 5.5 244 25 15.0 67.0 ±10 82 220 750
MH105S-18 5.0 4.5 - 5.5 241 25 18.0 56.0 ±10 83 220 750
MH105S-24 5.0 4.5 - 5.5 293 28 24.0 50.0 ±10 82 220 750
MH112S-03 12 10.8 - 13.2 108 15 3.3 303.0 ±20 77 220 250
MH112S-05 12 10.8 - 13.2 105 16 5.0 200.0 ±10 79 220 250
MH112S-09 12 10.8 - 13.2 105 15 9.0 111.0 ±10 79 220 250
MH112S-12 12 10.8 - 13.2 125 8 12.0 100.0 ±10 80 220 250
MH112S-15 12 10.8 - 13.2 105 17 15.0 67.0 ±10 79 220 250
MH112S-18 12 10.8 - 13.2 103 15 18.0 56.0 ±10 81 220 250
MH112S-24 12 10.8 - 13.2 127 25 24.0 50.0 ±10 79 220 250
MH124S-03 24 21.6 - 26.4 53 8 3.3 303.0 ±20 79 220 150
MH124S-05 24 21.6 - 26.4 53 8 5.0 200.0 ±10 79 220 150
MH124S-09 24 21.6 - 26.4 53 7 9.0 111.0 ±10 79 220 150
MH124S-12 24 21.6 - 26.4 63 8 12.0 100.0 ±10 80 220 150
MH124S-15 24 21.6 - 26.4 52 8 15.0 67.0 ±10 80 220 150
MH124S-18 24 21.6 - 26.4 51 8 18.0 56.0 ±10 82 220 150
MH124S-24 24 21.6 - 26.4 61 9 24.0 50.0 ±10 82 220 150

Notes: Units are available with 3.0 kV Isolation
1. Output load regulation is specifi ed for a load change of 20% to 100%. See the datasheet for the MH1xxS-xxI series
2. Operation at no-load will not damage these units. However, they may not meet all specifi cations.
3. These converters will operate without external components. However, to meet the specifi ed EMI Mechanical Dimensions
limits, a simple external input fi lter is required. See the input fi lter note below for more information.
4. All units are rated for operation at full output power to +85°C. Operation over +85°C without airfl ow
is not recommended. Output power should be derated linearly from 100% at 85°C to 0% at 100°C.
5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model
Selection table above for the correct rating.
Input Filter













The filter (C1, C2, C3 & L1) shown in the figure above
is required to meet EN 55022 level B. Recommended
VIN C1 L1 C2 C3
component values are shown in the table at right. (VDC) (µF) (µH) (µF) (pF) Pin Connections
Capacitor C1 is a 1210, 100V/ceramic, except for the
3.3 2.2 18.0
48V input which is a 100V/electrolytic. Capacitor C2 is a Pin Description
5.0 2.2 18.0
1210 100V/ceramic. Capacitor C3 is a 1206 2 kV/ceramic. 1-VIN
12 2.2 18.0
2+VIN
To meet the requirements of EN 61000-4-4 and EN 61000-4-5 24 2.2 18.0 2.2 470
, the value of capacitor C1 should be changed to 470 µF/100V. 3+VOUT
48 10.0 18.0 2.2 470
4-VOUT
All components should be mounted as close to the unit as
possible. Notes:
• All dimensions are typical in inches (mm)
MicroPower Direct • Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com