Page 2 - MPD - MD100MHI Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output
Model Voltage (VDC) Current (mA) Load Effi ciency Capacitive Fuse Rating
Number Voltage Current Current Regulation (%, Typ) Load Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) (µF, Max) (mA)
MD105MS-05HI 5 4.5 - 5.5 303 55 5.0 200.0 4.0 10 66 680 600
MD105MS-12HI 5 4.5 - 5.5 291 55 12.0 80.0 2.0 8 66 680 600
MD105MS-15HI 5 4.5 - 5.5 295 55 15.0 65.0 1.0 8 66 680 600
MD105MD-05HI 5 4.5 - 5.5 303 55 ±5.0 ±100.0 ±2.0 10 66 220 600
MD105MD-12HI 5 4.5 - 5.5 267 55 ±12.0 ±40.0 ±1.0 8 72 220 600
MD105MD-15HI 5 4.5 - 5.5 287 55 ±15.0 ±35.0 ±1.0 8 73 220 600
MD112MS-05HI 12 10.8 - 13.2 126 30 5.0 200.0 4.0 10 66 680 250
MD112MS-12HI 12 10.8 - 13.2 121 30 12.0 80.0 2.0 8 66 680 250
MD112MS-15HI 12 10.8 - 13.2 123 30 15.0 65.0 1.0 8 66 680 250
MD112MD-05HI 12 10.8 - 13.2 126 30 ±5.0 ±100.0 ±2.0 10 66 220 250
MD112MD-12HI 12 10.8 - 13.2 108 30 ±12.0 ±40.0 ±1.0 8 74 220 250
MD112MD-15HI 12 10.8 - 13.2 117 30 ±15.0 ±35.0 ±1.0 8 75 220 250
Notes: Derating Curve
1. The specifi ed maximum capacitive load is for each output.
2. Output load regulation is specifi ed for a load change of 20% to 100%.
3. When measuring output ripple, it is recommended that an external 0.33 µF
ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for single
output units and from each output to common for dual output units.
4. Operation at no-load will not damage these units. However, they may not meet
all specifi cations.
5. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC
output. To do this, connect the load across the positive (+VOUT) and negative
(-VOUT) outputs and fl oat the output common.
6. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.




Mechanical Dimensions


















Pin Connections
Pin Single Dual
1 +Vin +Vin
2 -Vin -Vin
5 -Vout -Vout
6 No Pin Common
7 +Vout +Vout
NC: No Connection






Mechanical Notes:
MicroPower Direct • All dimensions are typical in inch es (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
   1   2