Page 3 - MPD MD900RU Datasheet
P. 3



For applications that require meeting EMC standards, the diagrams below illustrate typi- www.micropowerdirect.com
cal connections of the MD900xRU series. Some notes on this diagram (starting with the
input circuit) are:
3. The output fi ltering components C9 & C11 are high frequency, low ESR electrolytic
1. An external fuse should be used in all power module applications. The recommended capacitors. Capacitors C10 & C12 are ceramic. Care must be taken in choosing
fuse is shown in the model chart on page 2. these capacitors not to exceed the capacitive load specifi cation for the unit. Voltage
2. To protect against voltage spikes, it is recommended that a TVS be used on the input. derating of capacitors should be 80% or above.
A suggested value is given in the tables below.
Typical Connection: 24 VIN, Single Output Models
Recommended component values are:
Component Value
C1 330 μF/100V
TVS 3KW, 70V
C2, C3, C4 1210 106M/35V
L1 20 μH
L2 20 μH
C5, C6, C7, C8 1808 221K/3kV
C9 10 μF
C10 1 μF



Typical Connection: 24 VIN, Dual Output Models

Component Value
C1 330 μF/100V
TVS 3KW, 70V
C2, C3, C4 1210 106M/35V
L1 20 μH
L2 20 μH
C5, C6, C7, C8 1808 221K/3kV
C9, C11 10 μF
C10, C12 1 μF


Typical Connection: 48 VIN, Single Output Models


Component Value
C1 330 μF/100V
TVS 3KW, 70V
C2, C3, C4 1210 106M / 35V
L1 132.8 μH
L2 10 μH
C5, C6, C7, C8 1808 221K/3kV
C9 10 μF
C10 1 μF


Typical Connection: 48 VIN, Dual Output Models


Component Value
C1 330 μF/100V
TVS 3KW, 70V
C2, C3, C4 1210 106M/35V
L1 132.8 μH
L2 10 μH
C5, C6, C7, C8 1808 221K/3kV
C9, C11 10 μF
C10, C12 1 μF