Page 4 - MPD MD300ERW Datasheet
P. 4



Input noise and surge suppression modules are available for The recommended input capacitor (C1) is a 330 µF/50V www.micropowerdirect.com
a number of MPD DC/DC power supplies. An MD300xERW for 5, 12, and 24 VDC input models and 330 µF/100V for
connection with the MDCFM-02A (noise suppression) module 48 VDC input units. The output capacitors (C2 & C3) are
connected to the input is shown in the diagrams below.
100 µF. For pricing or full technical information on these modules, please contact the factory.
Typical Connection: With MDCFM-02A Surge Suppression and Filter Modules, Single Output


















Typical Connection: With MDCFM-02A Surge Suppression and Filter Modules, Dual Output


















Mechanical Dimensions
Pin Con nec tions
Pin Single Output
1-V
IN
2+VIN
3 Remote On/Off
5 No Connection
6+VOUT
7-VOUT
8CS
Pin Dual Output
1-V
IN
2+VIN
3 Remote On/Off
5 No Connection
6+V
OUT
7 Common
8-VOUT





Notes:es:
Not

• All dimensions are typical in inches (mm) All dimensions are t
• Pin Section Toleranc
• Pin Section Tolerance x.xxx = ±0.004 (±0.100)
• General Tolerance x.xx = ±0.01 (±0.25)
• General Tolerance x
• Pin 1 is marked by a “dot” or indentation on the top of the unit
• Pin 1 is marked by a
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com