Page 2 - MPD MD200xEI Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Output
Model Load Capacitive Effi ciency Fuse Rating
Number Voltage (VDC) Current (mA) Voltage Current Current Regulation Load (%, Typ) Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Typ) (µF Max) (mA)
MD205S-03EI 5 4.5 - 5.5 334 35 3.3 400 40.0 18.0 220 79 700
UL MD205S-05EI 5 4.5 - 5.5 488 35 5.0 400 40.0 12.0 220 82 1,000
UL MD205S-09EI 5 4.5 - 5.5 488 35 9.0 222 22.0 9.0 220 82 1,000
UL MD205S-12EI 5 4.5 - 5.5 488 35 12.0 167 17.0 8.0 220 82 1,000
UL MD205S-15EI 5 4.5 - 5.5 482 35 15.0 133 13.0 7.0 220 83 1,000
UL MD205S-24EI 5 4.5 - 5.5 476 35 24.0 83 8.0 6.0 220 84 1,000
MD205D-03EI 5 4.5 - 5.5 555 35 ±3.3 ±303 ±30.0 18.0 100 72 1,000
UL MD205D-05EI 5 4.5 - 5.5 500 35 ±5.0 ±200 ±20.0 12.0 100 80 1,000
UL MD205D-09EI 5 4.5 - 5.5 476 35 ±9.0 ±111 ±11.0 9.0 100 84 1,000
UL MD205D-12EI 5 4.5 - 5.5 482 35 ±12.0 ±83 ±8.0 8.0 100 83 1,000
UL MD205D-15EI 5 4.5 - 5.5 488 35 ±15.0 ±67 ±7.0 7.0 100 82 1,000
UL MD205D-24EI 5 4.5 - 5.5 476 35 ±24.0 ±42 ±4.0 6.0 100 84 1,000
UL MD212S-05EI 12 10.8 - 13.2 203 20 5.0 400 40.0 12.0 220 82 500
UL MD212S-09EI 12 10.8 - 13.2 206 20 9.0 222 22.0 9.0 220 81 500
UL MD212S-12EI 12 10.8 - 13.2 198 20 12.0 167 17.0 8.0 220 84 500
UL MD212S-15EI 12 10.8 - 13.2 196 20 15.0 133 13.0 7.0 220 85 500
UL MD212S-24EI 12 10.8 - 13.2 194 20 24.0 83 8.0 6.0 220 86 500
MD212D-03EI 12 10.8 - 13.2 222 20 ±3.3 ±303 ±30.0 18.0 100 75 500
UL MD212D-05EI 12 10.8 - 13.2 208 20 ±5.0 ±200 ±20.0 12.0 100 80 500
UL MD212D-09EI 12 10.8 - 13.2 198 20 ±9.0 ±111 ±11.0 9.0 100 84 500
UL MD212D-12EI 12 10.8 - 13.2 196 20 ±12.0 ±83 ±8.0 8.0 100 84 500
UL MD212D-15EI 12 10.8 - 13.2 196 20 ±15.0 ±67 ±7.0 7.0 100 84 500
MD215S-05EI 15 13.5 - 16.5 167 15 5.0 400 40.0 12.0 220 80 400
MD215S-09EI 15 13.5 - 16.5 167 15 9.0 222 22.0 9.0 220 80 400
MD215S-12EI 15 13.5 - 16.5 165 15 12.0 167 17.0 8.0 220 81 400
MD215D-15EI 15 13.5 - 16.5 159 15 ±15.0 ±67 ±7.0 7.0 100 84 400
UL MD224S-05EI 24 21.6 - 26.4 104 10 5.0 400 40.0 12.0 220 80 200
UL MD224S-09EI 24 21.6 - 26.4 97 10 9.0 222 22.0 9.0 220 86 200
UL MD224S-12EI 24 21.6 - 26.4 99 10 12.0 167 17.0 8.0 220 84 200
UL MD224S-15EI 24 21.6 - 26.4 97 10 15.0 133 13.0 7.0 220 86 200
MD224S-18EI 24 21.6 - 26.4 97 10 18.0 111 11.0 7.0 220 86 200
UL MD224S-24EI 24 21.6 - 26.4 97 10 24.0 83 8.0 6.0 220 86 200
UL MD224D-05EI 24 21.6 - 26.4 104 10 ±5.0 ±200 ±20.0 12.0 100 80 200
UL MD224D-09EI 24 21.6 - 26.4 99 10 ±9.0 ±111 ±11.0 9.0 100 84 200
UL MD224D-12EI 24 21.6 - 26.4 99 10 ±12.0 ±83 ±8.0 8.0 100 84 200
UL MD224D-15EI 24 21.6 - 26.4 99 10 ±15.0 ±67 ±7.0 7.0 100 84 200

Notes: Derating Curve
1. Units that are marked with the ”UL“ in the model selection table
above are approved to EN 60950.
2. Output capacitive load is specifi ed for each output.
3. Output load regulation is specifi ed for a load change of 10% to 100%.
4. When measuring output ripple, it is recommended that an external 1 µF ceramic
capacitor & 10 µF electrolytic capacitor be placed in parallel from the +VOUT
pin to the -VOUT pin for single output models, or from each output to common
for dual output models.
5. Units with limited short circuit protection (MD205x-24E, MD224x-xxE Models)
must be restarted after a fault.
6. Models MD224D-15EI and MD224S-24EI have a typical isolation capaci-
tance of 50 pF.
7. Operation at no load will not damage these units, however, they may not meet
all specifi cations.
8. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.


MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com