Page 2 - MPD MD100xE Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Output
Model Load Capacitive Effi ciency Fuse Rating
Number Voltage (VDC) Current (mA) Voltage Current Current Regulation Load (%, Typ) Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Typ) (µF Max) (mA)
MD103S-03E 3.3 2.97 - 3.63 420 30 3.3 303.0 31.0 18.0 220 72 800
MD103S-05E 3.3 2.97 - 3.63 388 30 5.0 200.0 20.0 12.0 220 78 800
MD105S-03E 5.0 4.5 - 5.5 267 25 3.3 303.0 31.0 18.0 220 74 500
MD105S-05E 5.0 4.5 - 5.5 270 25 5.0 200.0 20.0 12.0 220 80 500
MD105S-09E 5.0 4.5 - 5.5 250 25 9.0 111.0 11.0 9.0 220 80 500
MD105S-12E 5.0 4.5 - 5.5 250 25 12.0 84.0 9.0 8.0 220 80 500
MD105S-15E 5.0 4.5 - 5.5 250 25 15.0 67.0 7.0 7.0 220 80 500
MD105S-24E 5.0 4.5 - 5.5 250 25 24.0 42.0 5.0 6.0 220 80 500
MD105D-03E 5.0 4.5 - 5.5 282 25 ±3.3 ±152.0 ±15.0 18.0 100 71 500
MD105D-05E 5.0 4.5 - 5.5 250 25 ±5.0 ±100.0 ±10.0 12.0 100 80 500
MD105D-09E 5.0 4.5 - 5.5 250 25 ±9.0 ±56.0 ±6.0 9.0 100 80 500
MD105D-12E 5.0 4.5 - 5.5 250 25 ±12.0 ±42.0 ±5.0 8.0 100 80 500
MD105D-15E 5.0 4.5 - 5.5 250 25 ±15.0 ±34.0 ±4.0 7.0 100 80 500
MD105D-24E 5.0 4.5 - 5.5 250 25 ±24.0 ±21.0 ±3.0 6.0 100 80 500
MD109D-09E 9.0 8.1 - 9.9 139 25 ±9.0 ±56.0 ±6.0 9.0 100 80 300
MD109D-15E 9.0 8.1 - 9.9 139 25 ±15.0 ±34.0 ±4.0 7.0 100 80 300
MD112S-03E 12 10.8 - 13.2 110 15 3.3 303.0 31.0 18.0 220 76 200
MD112S-05E 12 10.8 - 13.2 104 15 5.0 200.0 20.0 12.0 220 80 200
MD112S-09E 12 10.8 - 13.2 104 15 9.0 111.0 11.0 9.0 220 80 200
MD112S-12E 12 10.8 - 13.2 104 15 12.0 84.0 9.0 8.0 220 80 200
MD112S-15E 12 10.8 - 13.2 104 15 15.0 67.0 7.0 7.0 220 80 200
MD112S-24E 12 10.8 - 13.2 104 15 24.0 42.0 5.0 6.0 220 80 200
MD112D-03E 12 10.8 - 13.2 110 15 ±3.3 ±152.0 ±15.0 18.0 100 76 200
MD112D-05E 12 10.8 - 13.2 104 15 ±5.0 ±100.0 ±10.0 12.0 100 80 200
MD112D-09E 12 10.8 - 13.2 104 15 ±9.0 ±56.0 ±6.0 9.0 100 80 200
MD112D-12E 12 10.8 - 13.2 104 15 ±12.0 ±42.0 ±5.0 8.0 100 80 200
MD112D-15E 12 10.8 - 13.2 104 15 ±15.0 ±34.0 ±4.0 7.0 100 80 200
MD112D-24E 12 10.8 - 13.2 104 15 ±24.0 ±21.0 ±3.0 6.0 100 80 200
MD115S-05E 15 13.5 - 16.5 83 10 5.0 200.0 20.0 12.0 220 80 150
MD115S-12E 15 13.5 - 16.5 83 10 12.0 84.0 9.0 8.0 220 80 150
MD115S-15E 15 13.5 - 16.5 84 10 15.0 67.0 7.0 7.0 220 80 150
MD115D-05E 15 13.5 - 16.5 83 10 ±5.0 ±100.0 ±10.0 12.0 100 80 150
MD115D-12E 15 13.5 - 16.5 83 10 ±12.0 ±42.0 ±5.0 8.0 100 80 150
MD115D-15E 15 13.5 - 16.5 83 10 ±15.0 ±34.0 ±4.0 7.0 100 80 150
MD124S-03E 24 21.6 - 26.4 56 7 3.3 303.0 31.0 18.0 220 74 100
MD124S-05E 24 21.6 - 26.4 52 7 5.0 200.0 20.0 12.0 220 80 100
MD124S-09E 24 21.6 - 26.4 52 7 9.0 111.0 11.0 9.0 220 80 100
MD124S-12E 24 21.6 - 26.4 52 7 12.0 84.0 9.0 8.0 220 80 100
MD124S-15E 24 21.6 - 26.4 52 7 15.0 67.0 7.0 7.0 220 80 100
MD124S-24E 24 21.6 - 26.4 52 7 24.0 42.0 5.0 6.0 220 80 100
MD124D-05E 24 21.6 - 26.4 52 7 ±5.0 ±100.0 ±10.0 12.0 100 80 100
MD124D-09E 24 21.6 - 26.4 52 7 ±9.0 ±56.0 ±6.0 9.0 100 80 100
MD124D-12E 24 21.6 - 26.4 52 7 ±12.0 ±42.0 ±5.0 8.0 100 80 100
MD124D-15E 24 21.6 - 26.4 52 7 ±15.0 ±34.0 ±4.0 7.0 100 80 100
MD124D-24E 24 21.6 - 26.4 52 7 ±24.0 ±21.0 ±3.0 6.0 100 80 100
Notes:
1. Output load regulation is specifi ed for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor and a 10 µF electrolytic
capacitor be connected in parallel from the +VOUT pin to the -VOUT pin for single output models, or from each output to
common for dual output models. Short Circuit Protection
3. Operation at no load will not damage these units, however, they may not meet all specifi cations.
4. These converters are specifi ed for operation without external components. However, to meet specifi c EMC standards, Model Short Circuit Protection
some external components may be required. Typical connections are shown on page three.
5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection tables for MD105S-24E Momentary (1S)
the correct rating. MD105D-24E Momentary (1S)
Derating Curve MD124S-03E Momentary (1S)
MD124S-05E Momentary (1S)
MD124S-09E Momentary (1S)
MD124S-12E Momentary (1S)
MD124S-15E Momentary (1S)
MD124S-24E Momentary (1S)
MD124D-05E Momentary (1S)
MD124D-09E Momentary (1S)
MD124D-12E Momentary (1S)
MD124D-15E Momentary (1S)
MD124D-24E Momentary (1S)
All Other Models Continuous (Autorecovery)





MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com