Page 2 - MPD MD100SER Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output
Model Effi ciency Fuse Rating
Number Voltage (VDC) Current (mA) Voltage Current Current (%, Typ) Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (mA)
MD0705S-05ER 5 4.75 - 5.25 221 30 5.0 150 15.0 68 500
MD105S-05ER 5 4.75 - 5.25 303 30 5.0 200 20.0 66 600
MD105S-12ER 5 4.75 - 5.25 282 30 12.0 83 9.0 71 600
MD105S-15ER 5 4.75 - 5.25 274 30 15.0 67 7.0 73 600
MD105S-24ER 5 4.75 - 5.25 294 30 24.0 42 5.0 68 600
MD0712S-05ER 12 11.4 - 12.6 89 15 5.0 150 15.0 70 200
MD112S-05ER 12 11.4 - 12.6 124 15 5.0 200 20.0 67 250
MD112S-09ER 12 11.4 - 12.6 116 15 9.0 111 12.0 72 250
MD112S-12ER 12 11.4 - 12.6 119 15 12.0 83 9.0 70 250
MD112S-15ER 12 11.4 - 12.6 113 15 15.0 67 7.0 74 250
MD112S-24ER 12 11.4 - 12.6 123 15 24.0 42 5.0 68 250
MD0715S-05ER 15 14.25 - 15.75 74 15 5.0 150 15.0 68 150
MD115S-05ER 15 14.25 - 15.75 100 15 5.0 200 20.0 67 200
MD115S-15ER 15 14.25 - 15.75 93 15 15.0 67 7.0 72 200
MD115S-24ER 15 14.25 - 15.75 98 15 24.0 42 5.0 68 200
MD0724S-05ER 24 22.8 - 25.2 46 8 5.0 150 15.0 68 100
MD124S-05ER 24 22.8 - 25.2 61 8 5.0 200 20.0 68 125
MD124S-09ER 24 22.8 - 25.2 61 8 9.0 111 12.0 68 125
MD124S-12ER 24 22.8 - 25.2 57 8 12.0 83 9.0 73 125
MD124S-15ER 24 22.8 - 25.2 56 8 15.0 67 7.0 75 125
MD124S-24ER 24 22.8 - 25.2 61 8 24.0 42 5.0 68 125
Notes: Derating Curve
1. Operation at no load will not damage these units. However, they may not meet all specifi cations.
2. These converters will operate without external components. However, when measuring output ripple, it is
recommended that an external capacitor be placed from the +Vout pin to the -Vout pin. An input capacitor
will enhance stability over temperature and input line variations. For applications requiring very low output
noise levels, a simple LC fi lter, as shown in the connection diagram below, should be effective. Recommended
component values are given in the table below the diagram.
3. Units that are specifi ed for momentary short circuit protection must be restarted after a fault.










Mechanical Dimensions
VIN C1 L1 VOUT L2 C2
5 VDC 4.7 µF/50V 4.7 - 10 µH 5 VDC 4.7 - 10 µH 10 µF
12 VDC 4.7 µF/50V 4.7 - 10 µH 9 VDC 4.7 - 10 µH 4.7 µF
15 VDC 2.2 µF/50V 4.7 - 10 µH 12 VDC 4.7 - 10 µH 2.2 µF
24 VDC 1.0 µF/50V 4.7 - 10 µH 15 VDC 4.7 - 10 µH 1.0 µF
24 VDC 4.7 - 10 µH 0.47 µF
3. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections

Pin Function
1+VIN
2-VIN
4-VOUT
6+VOUT



MicroPower Direct Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less! • Pin 1 is marked by a “dot” or indentation on the unit
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com