Page 1 - MPD MD100ERW Datasheet
P. 1



MD100ERW Series





2:1 Input, 1W SIP,

Single & Dual Output


DC/DC Con vert ers

Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Key Features: Input
Parameter Conditions Min. Typ. Max. Units
• 1W Output Power 5 VDC Input 4.5 5.0 9.0
12 VDC Input 9.0 12.0 18.0
• 2:1 Input Voltage Range Input Voltage Range VDC
24 VDC Input 18.0 24.0 36.0
• Short Circuit Protected 48 VDC Input 36.0 48.0 75.0
5 VDC Input 3.5 4.0 4.5
• 1,500 VDC Isolation 12 VDC Input 4.5 8.0 9.0
Input Start Voltage VDC
• 29 Standard Models 24 VDC Input 11.0 16.0 18.0
48 VDC Input 24.0 33.0 36.0
• Miniature SIP Case Input Filter Capacitor Filter
• -40°C to +85°C Operation Output
Parameter Conditions Min. Typ. Max. Units
• Industry Standard Pin-Out Output Voltage Accuracy, See Note 1 IOUT = 5% to 100% ±1.0 ±3.0 %
• Low Cost Output Voltage Balance, See Note 2 Dual Outputs, Balanced Loads ±0.5 ±1.0 %
Line Regulation VIN = Min to Max ±0.3 ±0.5 %
Load Regulation IOUT = 5% to 100% ±0.4 ±0.75 %
Ripple (20 MHz) See Note 3 30 50 mV P - P
Noise (20 MHz) See Note 3 55 75 mV P - P
Transient Recovery Time, See Note 4 25% Load Step Change 0.5 2.0 mSec
Transient Response Deviation ±2.5 ±5.0 %
Temperature Coeffi cient ±0.02 ±0.03 %/°C
Output Short Circuit Continuous (Autorecovery)
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage 60 Seconds 1,500 VDC
Isolation Resistance 500 VDC 1,000 M
Isolation Capacitance 100 kHz/0.1V 120 pF
Switching Frequency 200 kHz
EMI Characteristics
Parameter Standard Level
Radiated Emissions See Note 5 EN 55022 Class B
Conducted Emissions See Note 5 EN 55022 Class B
ESD EN 61000-4-2 Criteria B; ±4 kV Contact
RS EN 61000-4-3 Criteria A; 10V/m
See Note 6 EN 61000-4-4 Criteria B; ±2 kV
EFT
See Note 6 EN 61000-4-4 Criteria B; ±4 kV
Surge See Note 7 EN 61000-4-5 Criteria B; ±2 kV
CS EN 61000-4-6 Criteria A; 3 Vrms
Voltage Dips EN 61000-4-29 Criteria B; 0% - 70%
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -40 +25 +85 °C
Storage Temperature Range -55 +125 °C
Cooling Free Air Convection
MicroPower Direct Humidity RH, Non-condensing 95 %
292 Page Street Physical
Suite D Case Size 0.866 x 0.374 x 0.472 Inches (22.00 x 9.50 x 12.00 mm)
Stoughton, MA 02072 Case Material Non-Conductive Black Plastic (UL94-V0)
USA Weight 0.17 Oz (4.9g)
Reliability Specifi cations
T: (781) 344-8226 Parameter Conditions Min. Typ. Max. Units
F: (781) 344-8481 MTBF MIL HDBK 217F, 25°C, Gnd Benign 1.0 MHours
E: sales@micropowerdirect.com Absolute Maximum Ratings
W: www.micropowerdirect.com Parameter Conditions Min. Typ. Max. Units
5 VDC Input -0.7 12.0
12 VDC Input -0.7 25.0
Input Voltage Surge (1 Sec) VDC
24 VDC Input -0.7 50.0
48 VDC Input -0.7 100.0
Lead Temperature 1.5 mm From Case for 10 Sec 300 °C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
   1   2   3   4