Page 1 - MPD MD100xEHI Datasheet
P. 1





MD100xEHI Series



Low Cost, 1W

6 kV Isolation, SIP

DC/DC Con vert ers


Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Key Features: Input
Parameter Conditions Min. Typ. Max. Units
• 1W Output Power
5 VDC Input 4.50 5.0 5.50
• Miniature SIP Case 12 VDC Input 10.80 12.0 13.20
Input Voltage Range VDC
• Short Circuit Protected 15 VDC Input 13.50 15.0 16.50
24 VDC Input 21.60 24.0 26.40
• 6,000 VDC Isolation
Input Filter Internal Capacitor
• Single and Dual Outputs Output
• >3.5 MHour MTBF Parameter Conditions Min. Typ. Max. Units
• -40°C to +105°C Operation Output Voltage Accuracy ±2.5 %
Line Regulation For VIN Change of 1% ±1.2 %
• LOW COST
Load Regulation, See Note 1 See Model Selection Guide
Output Voltage <12 VDC 100
Ripple & Noise (20 MHz), See Note 2 mV P - P
15 VDC, 24 VDC Output 150
Temperature Coeffi cient ±0.03 %/°C
Output Short Circuit Continuous (Autorecovery)
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage 60 Seconds 6,000 VDC
Isolation Resistance 500 VDC 1,000 M
Isolation Capacitance 100 kHz, 0.1V 10 pF
Switching Frequency 50 kHz
EMI Characteristics
Parameter Conditions Min. Typ. Max. Units
Conducted CISPR22/EN 55022 Level B
EMI Compliance, See Note 3
Radiated CISPR22/EN 55022 Level B
EMC Compliance, Electrostatic Discharge (ESD) EN 61000-4-2 Level B Contact ±8 kV
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -40 +25 +105 °C
Storage Temperature Range -55 +125 °C
Cooling Free Air Convection
Humidity RH, Non-condensing 95 %
Physical
Case Size 0.768 x 0.386 x 0.492 Inches (19.5 x 9.8 x 12.5 mm)
Case Material Non-Conductive Black Plastic (UL-94V0)
Weight 0.14 Oz (4.2g)
MicroPower Direct Reliability Specifi cations
292 Page Street Parameter Conditions Min. Typ. Max. Units
Suite D
Stoughton, MA 02072 MTBF MIL HDBK 217F, 25°C, Gnd Benign 3.5 MHours
USA Safety Standards, See Note 5 UL 60950, EN 60950
Safety Approvals, See Note 5 UL 60950, File No. E245422
T: (781) 344-8226 Absolute Maximum Ratings
F: (781) 344-8481 Parameter Conditions Min. Typ. Max. Units
E: sales@micropowerdirect.com
5 VDC Input -0.7 9.0
W: www.micropowerdirect.com
12 VDC Input -0.7 18.0
Input Voltage Surge (1 Sec) VDC
15 VDC Input -0.7 21.0
24 VDC Input -0.7 30.0
Lead Temperature 1.5 mm From Case For 10 Sec 300 °C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com