Page 2 - MPD MPM-05MS Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com

Input Current Output Capacitive Over
Model (mA Typ) Voltage Effi ciency
Number Voltage Current (mA) Load Protection (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (µF, Max) (VDC, Max)
MPM-05MS-05 120 70 5.0 1,000 0.00 4,000 7.5 76
MPM-05MS-12 120 70 12.0 420 0.00 820 16.0 80
MPM-05MS-15 120 70 15.0 333 0.00 820 20.0 81
MPM-05MS-24 120 70 24.0 230 0.00 330 30.0 81

Notes: 6. All units are rated for EN 61000-4-4 (±2 kV) with the addition
1. Operation at no load will not damage the units, however, they of the MOV and NTC shown in the typical connection below.
may not meet all specifi cations. They will meet EN 61000-4-4 (±4 kV) with the additional MPD offers a wide variety of input protection
2. Inrush current is given for a cold start at 25°C. input components shown in the typical connection diagram and fi ltering modules for use with our AC & DC
shown on page 3.
3. When measuring output ripple, it is recommended that an power modules. The MACFM-02A may be used
7. All units are rated for EN 61000-4-5 (±1 kV) with the addition of
external 0.1 µF high frequency ceramic capacitor be placed
the MOV and NTC shown in the typical connection below. They will with the MPM-05MS, as shown on page 3. Full
in parallel with a 47 µF high frequency electrolytic capacitor meet EN 61000-4-5 (±2 kV /±4 kV) with the input components datasheets for all our input modules are available
from the +VOUT pin to the -VOUT pin. shown in the typical connection diagram on page 3. on our website, or call the factory for a more help.
4. The max lead temp for wave soldering is ±5% for a time 8. It is recommended that a fuse be used on the input of a
period of 5 to 10S. For hand soldering, it is ±10% for 3 to 5S. power supply for protection. For the MPM-05MS series,
5. All units are rated for EN 55022 (CE/RE) class B without a 2.0A/250 VAC slow blow should be used.
external components.
Typical Connection

















The diagram above illustrates a typical application connection of the MPM-05MS series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The They will meet EN 61000-4-5 (±2 kV /±4 kV) with the input Model C1 C2
recommended fuse is a 2.0A/250 VAC slow blow. The NTC a 5D9. components shown in the typical connection diagram on page 3.
2. All units are rated for EN 55022 (CE/RE) class B without external 5. If output noise levels lower than the specifi ed limits are required, MPM-05MS-05 1.0 µF/50V 220 µF/10V
components. the addition of C1 and C2 should be suffi cient for most applications. MPM-05MS-12 1.0 µF/50V 100 µF/25V
3. All units are rated for EN 61000-4-4 (±2 kV) with the addition of The recommended values are shown in the table at right. The MPM-05MS-15 1.0 µF/50V 100 µF/25V
the MOV and NTC shown in the typical connection above. They will output fi ltering capacitor C2 is a high frequency, low resistance
meet EN 61000-4-4 (±4 kV) with the additional input components electrolytic capacitor. Capacitor C1 is ceramic. Voltage derating of MPM-05MS-24 1.0 µF/50V 47 µF/35V
shown in the typical connection diagram shown on page 3. capacitors should be 80% or above.
4. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) with the addi- 6. The TVS is added to protect circuits being powered from damage
tion of the MOV and NTC shown in the typical connection above. if the module fails.

Derating Curve Input Voltage Vs Load
























MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com