Page 1 - MPD MPU-60S Datasheet
P. 1





MPU-60S Series



Single Output, 60W


Compact, U-Channel

AC/DC Power Supplies



Electrical Specifi cations
Key Features: Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Input
• 60W Output Power Parameter Conditions Min. Typ. Max. Units
• Universal 90-265 AC Input Universal 90 265 VAC
Input Voltage Range
120 370 VDC
• EN 60950 Approved
Input Frequency 47 63 Hz
• Low Leakage Current Input Filter Meets EN 55022 Class B; FCC Class B
• Six Single Output Models Input Current See Model Selection Guide
Cold Start, 115 VAC 30.0
• Meets EN 55022 B Inrush Current A Pk
Cold Start, 230 VAC 50.0
• >130 kHour MTBF Safety Ground Leakage Current 0.5 mA
• “Finger Safe” Cover Avail. Output
Parameter Conditions Min. Typ. Max. Units
• DIN Rail Kit Available
Output Voltage/Current See Model Selection Guide
Output Voltage Tolerance ±2.0 %
Line Regulation Vin = Min to Max ±1.0 %
Load Regulation Iout = 5% to 100% ±1.0 %
Ripple & Noise (20 MHz) See Note 1
Hold-Up Time 115 VAC 10 mSec
Temperature Coeffi cient ±0.02 %/°C
Over Voltage Protection See Model Selection Guide
Overload Protection See Note 2 125 150 %
Short Circuit Protection Continuous (Autorecovery)
General
Parameter Conditions Min. Typ. Max. Units
3,000 VAC
Input to Output
4,242 VDC
Isolation Voltage
Input to Ground 1,500 VAC
Output to Ground 500 VAC
Switching Frequency Fixed 100 kHz
EMI Characteristics
Parameter Standard Criteria Level
Radiated Emissions EN 55022 B
Conducted Emissions EN 55022 B
Noise Immunity (EMS) EN 55024
±1 kV (L-N)
Surge EN 61000-4-4
±2 kV (L-FG & N-FG)
Environmental
Parameter Conditions Min. Typ. Max. Units
MicroPower Direct Operating Temperature Range Ambient -40 +25 +70 °C
292 Page Street
Suite D Storage Temperature Range -50 +84 °C
Stoughton, MA 02072 Cooling Free Air Convection (See Derating Curve)
USA Humidity RH, Non-condensing 95 %
Physical
T: (781) 344-8226 Size See Mechanical Drawings
F: (781) 344-8481 U-Channel 8.46 Oz (0.240 kg)
E: sales@micropowerdirect.com Weight With Cover 9.17 Oz (0.260 kg)
W: www.micropowerdirect.com Reliability Specifi cations
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 130 kHours
Safety Standards UL 1950, EN 60950
Vibration 10~500 Hz, 5G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
www.micropowerdirect.com