Page 1 - MPD - MPO-60S-Datasheet
P. 1





MPO-60S Series



Single Output, 60W


Compact, Open Frame

AC/DC Power Supplies



Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Key Features:
Input
• 60W Output Power Parameter Conditions Min. Typ. Max. Units
• Universal 90-264 AC Input Input Voltage Range Universal 90 264 VAC
120 370 VDC
• EN 60950 Approved
Input Frequency 47 63 Hz
• Low Leakage Current Input Current See Model Selection Guide
• Six Single Output Models Cold Start, 115 VAC 30.0
Inrush Current A Pk
Cold Start, 230 VAC 50.0
• Meets EN 55022 B
Safety Ground Leakage Current 0.50 mA
• >130 kHour MTBF Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage/Current See Model Selection Guide
Output Voltage Accuracy ±2.0 %
Line Regulation VIN = Min to Max ±1.0 %
Load Regulation IOUT = 5% to 100% ±1.2 %
Ripple & Noise (20 MHz) See Note 1
Hold-Up Time 115 VAC 10 mSec
Temperature Coeffi cient ±0.02 %/°C
Over Voltage Protection, See Note 2 See Model Selection Guide
Overload Protection See Note 3 125 180 %
Short Circuit Protection Continuous (Autorecovery)
General
Parameter Conditions Min. Typ. Max. Units
3,000 VAC
Input to Output
4,242 VDC
Isolation Voltage
Input to Ground 1,500
VAC
Output to Ground 500
Switching Frequency 65 kHz
EMI Characteristics
Parameter Standard Criteria Level
Radiated Emissions EN 55022 B
Conducted Emissions EN 55022 B
Noise Immunity (EMS) EN 55024
±1 kV (L-N)
Surge EN 61000-4-4
±2 kV (L-FG & N-FG)
Environmental
MicroPower Direct Parameter Conditions Min. Typ. Max. Units
292 Page Street Operating Temperature Range Ambient -40 +25 +70 °C
Suite D Storage Temperature Range -50 +85 °C
Stoughton, MA 02072 Cooling Free Air Convection (See Derating Curve)
USA Humidity RH, Non-condensing 95 %
Physical
T: (781) 344-8226 Size See Mechanical Drawing (Page 3)
F: (781) 344-8481
E: sales@micropowerdirect.com Weight 8.46 Oz (0.240 kg)
W: www.micropowerdirect.com Reliability Specifi cations
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 130 kHours
Safety Standards UL 1950, EN 60950
Vibration 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis

www.micropowerdirect.com
   1   2   3