Page 4 - MPD - MPO-500S-Datasheet
P. 4



Air Flow www.micropowerdirect.com







To operate the unit with a load over
240W, air fl ow must be provided.
The diagram at left shows the
approximate area where the airfl ow
should be directed.




Mechanical Dimensions










































Connections Output Connector (CN2): Logic Signal Connector (CN3): Fan Driver Connector (CN4):
• Terminal Block: • Mating Part No: • Mating Part No:
Input Connector (CN1): Dinkle DT-2C-B07W-06: M3 Screws PHD-H20-2X04 or equivalent CX-H250-02 or equivalent
• Terminal Block: 6 terminals, 7.62 mm Centers (Cherg Weei Technology Corp) (Cherg Weei Technology Corp)
Dinkle DT-2C-B07W-03: M3 Screws Suitable Wire = 22 - 14 AWG
3 terminals, 7.62 mm Centers Pin Function
Suitable Wire = 22 - 14 AWG Pin Function 1 -5 SB Pin Function
1 +12V
Pin Function 1+VOUT 2 +5 SB 2 GND
1 Field Ground 2+VOUT 3 GND
2 AC-Neutral 3+VOUT 4 DC OK
3 AC-Line 4-VOUT 5 -RC
5-VOUT 6 +RC
6-VOUT 7 -S
8 +S
See page 2 for more information
on the signals available from CN3
MicroPower Direct


We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com