Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Key Features: Input
• 500W Power W/30 CFM Parameter Conditions Min. Typ. Max. Units
Universal 90 264 VAC
• Universal 90-264 AC Input Input Voltage Range 120 370 VDC
• >0.95 Active PFC Input Frequency 47 63 Hz
Input Current See Model Selection Guide
• EN 60950 Approved Cold Start, 115 VAC 35.0
Inrush Current A Pk
• Standby 5V Output Cold Start, 230 VAC 70.0
Safety Ground Leakage Current 0.50 mA
• Three Single Output Models
Power Factor Correction, See Note 1 0.95
• Meets EN 55022 B Output
• >160 kHour MTBF Parameter Conditions Min. Typ. Max. Units
Max Output Power 500W (with 30 CFM), 240W (230 VAC), 230W (115 VAC)
• Only 5.0” x 3.0” x 1.4” Output Voltage Accuracy ±2.0 %
Line Regulation VIN = 115 to 264 VAC ±1.0 %
12 VOUT ±1.2
Load Regulation, See Note 2 %
24 and 48 VOUT ±1.0
12 VDC Output 150
Ripple & Noise (20 MHz), See Note 3 24 VDC Output 240 mV P - P
48 VDC Output 480
Hold-Up Time 115 VAC, 90% VOUT 8 mSec
0°C - 50°C ±0.03
Temperature Coeffi cient %/°C
-30°C - 0°C ±0.06
Over Temperature Protection Autorecovery 120 °C
Over Voltage Protection See Model Selection Guide
Overload Protection 120 170 %
Short Circuit Protection, See Note 4 Continuous (Autorecovery)
General
Parameter Conditions Min. Typ. Max. Units
3,000 VAC
Input to Output
4,242 VDC
Isolation Voltage
Input to Ground 1,500
Output to Ground 500 VAC
Switching Frequency 58 75 kHz
EMI Characteristics
Parameter Standard Criteria Level
Radiated Emissions EN 55022 A
Conducted Emissions EN 55022 B
Noise Immunity (EMS) EN 55024
Surge EN 61000-4-4 ±1 kV (L-N), ±2 kV (L-G)
MicroPower Direct Environmental
292 Page Street Parameter Conditions Min. Typ. Max. Units
Suite D Operating Temperature Range Ambient -30 +25 +70 °C
Stoughton, MA 02072 Storage Temperature Range -30 +85 °C
USA
Cooling Free Air Convection (See Derating Curve)/30 CFM
Humidity RH, Non-condensing 95 %
T: (781) 344-8226 Physical
F: (781) 344-8481 Size See Mechanical Drawing (Page 4)
E: sales@micropowerdirect.com
Weight 16.22 Oz (0.460 kg)
W: www.micropowerdirect.com
Reliability Specifi cations
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 160 kHours
Safety Standards UL 1950, EN 60950
Vibration 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis