Page 2 - MPD MPM-60PB Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Maximum Maximum
Model Capacitive Output Effi ciency
Current (A) Current
Number Voltage Load Power (%, Typ)
115 VAC 230 VAC (VDC) Max. (A) Min. (%) (µF) (W)
MPM-60S-05PB 2.0 1.0 5.0 10.0 1.0 80,000 50.0 82
MPM-60S-09PB 2.0 1.0 9.0 6.66 1.0 28,000 60.0 84
MPM-60S-12PB 2.0 1.0 12.0 5.00 1.0 14,000 60.0 86
MPM-60S-15PB 2.0 1.0 15.0 4.00 1.0 12,000 60.0 86
MPM-60S-24PB 2.0 1.0 24.0 2.50 1.0 4,000 60.0 86
MPM-60S-48PB 2.0 1.0 48.0 1.25 1.0 950 60.0 86
Notes: Derating Curve
1. Ripple and noise are measured at 20 Mhz
bandwidth with a 0.1µF and a 47 µF capacitor
connected in parallel as close to the unit output
terminals as possible.
2. Output short circuit protection is provided by a “hiccup
mode” circuit. The unit recovers automatically when
the fault condition is removed.
3. Operation at under no load conditions will not damage
these units.
4. It is recommended that a fuse be used on the
input of a power supply for protection. For the
MPM-60PB series, a 4A/250 VAC slow blow
should be used.














Mechanical Dimensions

























Pin Connections
Pin Function
1 AC-Neutral
2 AC-Line
3FG
4 +Vout
5 -Vout
6 Trim

Notes:
MicroPower Direct • All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com