Page 1 - MPD MPM-60PB Datasheet
P. 1





MPM-60PB Series



Single Output, 60W


Compact “Power Brick”

AC/DC Power Supplies




Key Features: Electrical Specifi cations
Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
• 60W Output Power
Input
• High Power Density Case Parameter Conditions Min. Typ. Max. Units
• Universal 85-265 VAC Input 85 265 VAC
Input Voltage Range
• EN 60950 Approved (UL) 100 370 VDC
Input Frequency 47 63 Hz
• -40°C to + 70°C Operation Input Current See Model Selection Guide
• Meets EN 55022 B 115 VAC 30.0
Inrush Current A Pk
• 4,000 VAC I/O Isolation 230 VAC 50.0
Leakage Current 0.5 mA
• >130 kHour MTBF EMI Meets CISPR Pub. 22/FCC Class B
EMC Meets EN 55024
Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Accuracy ±2.0 %
Output Voltage Adjustment ±10.0 %
Line Regulation VIN = Min to Max ±1.0 %
Load Regulation IO = 5% to 100% ±1.0 %
Ripple (20 MHz), See Note 1 <±0.2% Vout + 40 mV mVP-P
Noise, See Note 1 <±0.5% Vout + 50 mV mVP-P
115 VAC 10
Hold-Up Time mSec
230 VAC 60
Temperature Coeffi cient ±0.02 %/°C
Over Voltage Protection Zener Diode Clamp 120 % of VO
Short Circuit Protection, See Note 2 Continuous (Autorecovery)
Overload Protection 150 % of IO
General
Parameter Conditions Min. Typ. Max. Units
Input to Output 4,000
Isolation Voltage Input to FG 1,500 VAC
Output to FG 500
Isolation Resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) EN 61000-4-2 Level B
RF Field Susceptibility EN 61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV
Surge EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency 100 kHz
MicroPower Direct Environmental
292 Page Street Parameter Conditions Min. Typ. Max. Units
Suite D Operating Temperature Range Ambient -40 +25 +70 °C
Stoughton, MA 02072 Storage Temperature Range -50 +85 °C
USA Cooling Free Air Convection (See Derating Curve)
Humidity RH, Non-condensing 95 %
T: (781) 344-8226 Physical
F: (781) 344-8481 Case Size 4.30 x 2.30 x 1.18 Inches (109.0 x 58.5 x 30.0 mm)
E: sales@micropowerdirect.com Case Material Non-Conductive Plastic & Fiberglass (UL94-V0)
W: www.micropowerdirect.com Weight 10.92 Oz (310g)
Reliability Specifi cations
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 130 kHours
Safety Standards UL 60950, EN 60950
Safety Approvals UL, cUL; File No. E245422
www.micropowerdirect.com