Page 1 - MPD MPM-40E Datasheet
P. 1





MPM-40E Series



Low Cost, Encapsulated


Single Output, 40W

AC/DC Power Supplies



Key Features: Electrical Specifi cations
Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
• 40W Output Power
Input
• Universal 85-264 VAC Input Parameter Conditions Min. Typ. Max. Units
• EN 60950 Approved (UL) 85 264 VAC
Input Voltage Range
• Meets IEC Safety Class II 120 370 VDC
Input Frequency 47 440 Hz
• Industry Standard Pin-Out
Input Current See Model Selection Guide
• Meets EN 55022 Class B 115 VAC 30.0
Inrush Current A Pk
• >200 kHour MTBF 230 VAC 50.0
• Low Cost Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Standby Power 0.5 W
Output Voltage Accuracy ±2.0 %
Line Regulation VIN = Min to Max ±0.5 %
Load Regulation See Note 2 ±1.0 %
Ripple & Noise (20 MHz) 50 100 mV P-P
115 VAC 15
Hold-Up Time mSec
230 VAC 80
Temperature Coeffi cient ±0.02 %/°C
Short Circuit Protection Continuous (Autorecovery)
Over Voltage Protection Zener Diode Clamp
Overload Protection Autorecovery 110 %W
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage 60 Sec 3,000 VAC
Isolation Resistance 500 VDC 100 M
EMI Characteristics
Parameter Standard Min. Typ. Max. Units
Radiated Emissions EN 55022 Class B
Conducted Emissions EN 55022 Class B
ESD EN 61000-4-2 Criteria B; ±8 kV Air/±6 kV Contact
RS EN 61000-4-3 Criteria A; 10V/m
EFT EN 61000-4-4 Criteria B; ±2 kV
Surge See Note 4 EN 61000-4-5 Criteria B; ±1 kV/ ±2 kV
CS EN 61000-4-6 Criteria A; 10 Vrms
PFMF EN 61000-4-8 Criteria A; 10A/m
Voltage Dips EN 61000-4-11 Criteria B; 95% 5000 mS
Switching Frequency 65 kHz
Environmental
MicroPower Direct Parameter Conditions Min. Typ. Max. Units
292 Page Street Operating Temperature Range Ambient -40 +25 +70 °C
Suite D Operating Temperature Range Case +90 °C
Stoughton, MA 02072 Storage Temperature Range -40 +85 °C
USA Cooling Free Air Convection (See Derating Curve)
Humidity RH, Non-condensing 95 %
T: (781) 344-8226 Physical
F: (781) 344-8481 Case Size 3.50 x 2.50 x 0.984 Inches (89.0 x 63.5 x 25.0 mm)
E: sales@micropowerdirect.com Case Material Non-Conductive Black Plastic (UL94-V0)
W: www.micropowerdirect.com Weight 8.8 Oz (250g)
Reliability Specifi cations
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 200 kHours
Safety Standards EN 60950
Safety Class IEC 61140 Class II
www.micropowerdirect.com
   1   2