Page 2 - MPD MPM-30IS Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3) Capacitive
Model Effi ciency
Current (A) Voltage Current (A) Voltage Current (A) Voltage Current (A) Load
Number (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (VDC) Max. Min. (VDC) Max. Min. (µF, Max)
MPM-30S-05IS 0.557 0.14 5.0 6.000 0.600 8,000 78
MPM-30S-12IS 0.543 0.14 12.0 2.500 0.250 3,900 80
MPM-30S-15IS 0.543 0.14 15.0 2.000 0.200 3,900 80
MPM-30S-24IS 0.543 0.14 24.0 1.250 0.125 1,500 80
MPM-30S-48IS 0.543 0.14 48.0 0.625 0.063 1,000 80
MPM-30D-12IS 0.565 0.14 +12.0 +1.300 +0.130 -12.0 -1.300 -0.130 ±1,500 80
MPM-30D-15IS 0.543 0.14 +15.0 +1.000 +0.100 -15.0 -1.000 -0.100 ±1,500 80
MPM-30T-0512IS 0.572 0.14 5.0 3.000 +0.600 +12.0 +0.600 +0.120 -12.0 -0.600 -0.120 See Note 6 76
MPM-30T-0512ISA 0.572 0.14 5.0 3.000 +0.600 +12.0 +1.000 +0.200 -12.0 -0.250 -0.050 See Note 6 76
MPM-30T-0515IS 0.572 5.0 3.000 +0.300 +15.0 +0.500 +0.050 -15.0 -0.500 -0.050 See Note 6 76
MPM-30T-5312IS 0.588 5.0 4.500 +0.900 +3.3 +1.000 +0.220 +12.0 +0.250 +0.050 See Note 6 71
MPM-30T-3512IS 0.483 3.3 4.000 +0.800 +5.0 +1.500 +0.300 +12.0 +0.250 +0.050 See Note 6 71
Derating Curve
Other output combinations are available
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. For triple output models, the output voltage accuracy of the auxilliary
outputs is typically ±4%.
2. Load regulation is measured for an output change of 0% to 100% at
nominal input line. For multiple output models, the loads are balanced.
3. Operation at no-load will not damage these units. However, they may not
meet all specifi cations.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit.
6. For triple output models, the maximum capacitive load for 5 VDC and
3.3VDC outputs is 2,200 µF. For all other outputs it is ±1,500 µF.
7. The MPM-30IS series includes a built-in 3.5A/250 VAC fuse. It is
recommended that an external 1.5A slow blow fuse also be used on the
input for protection.

Model Number
Mechanical Dimensions



















Pin Connections
Pin Single Dual Triple
1 AC-Neutral
2 AC-Line
3 +Vo +Vo +Vo 2
4NP NP +Vo 1
5 -Vo Common Common 2/3
6NP NP -Vo 1
7 NP -Vo +Vo 3
NC = No Connection





MicroPower Direct Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com