Page 2 - MPD MPM-30CM Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3)
Capacitive Effi -
Model Current (A) Current (A) Current (A) Current (A)
Number Voltage Voltage Voltage Load ciency
115 VAC 230 VAC (VDC) Max. Min. (VDC) Max. Min. (VDC) Max. Min. (µF, Max) (%, Typ)
MPM-30S-05CM 0.557 0.14 5.0 6.000 0.600 8,000 78
MPM-30S-12CM 0.543 0.14 12.0 2.500 0.250 3,900 80
MPM-30S-15CM 0.543 0.14 15.0 2.000 0.200 3,900 80
MPM-30S-24CM 0.543 0.14 24.0 1.250 0.125 1,500 80
MPM-30S-48CM 0.543 0.14 48.0 0.625 0.063 1,000 80
MPM-30D-12CM 0.565 0.14 +12.0 +1.300 +0.130 -12.0 -1.300 -0.130 ±1,500 80
MPM-30D-15CM 0.543 0.14 +15.0 +1.000 +0.100 -15.0 -1.000 -0.100 ±1,500 80
MPM-30T-0512CM 0.572 0.14 5.0 3.000 +0.600 +12.0 +0.600 +0.120 -12.0 -0.600 -0.120 See Note 6 76
MPM-30T-0512CMA 0.572 0.14 5.0 3.000 +0.600 +12.0 +1.000 +0.200 -12.0 -0.250 -0.050 See Note 6 76
MPM-30T-0515CM 0.572 5.0 3.000 +0.300 +15.0 +0.500 +0.050 -15.0 -0.500 -0.050 See Note 6 76
MPM-30T-5312CM 0.588 5.0 4.500 +0.900 +3.3 +1.000 +0.220 +12.0 +0.250 +0.050 See Note 6 71
MPM-30T-3512CM 0.483 3.3 4.000 +0.800 +5.0 +1.500 +0.300 +12.0 +0.250 +0.050 See Note 6 71
Derating Curve
Other output combinations are available
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. For triple output models, the output voltage accuracy of the auxilliary outputs is typically ±4%.
2. Load regulation is measured for an output change of 0% to 100% at nominal input line. For multiple
output models, the loads are balanced.
3. Operation at no-load will not damage these units. However, they may not meet all specifi cations.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automati-
cally when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit.
6. For triple output models, the maximum capacitive load for 5 VDC and 3.3VDC outputs is 2,200 µF.
For all other outputs it is ±1,500 µF.
7. The MPM-30CM series includes a built-in 3.5A/250 VAC fuse. It is recommended that an
external 1.5A slow blow fuse also be used on the input for protection.



Pin Connections Mechanical Dimensions, Chassis Mount
Pin Single Dual Triple
1 AC-Neutral
2 AC-Line
3 +Vo +Vo +Vo 2
4NC NC +Vo 1
5 -Vo Common Common 2/3
6NC NC -Vo 1
7 NC -Vo +Vo 3
NC = No Connection


Model Number















A DIN Rail mounting kit is available
Contact the factory for details at:
sales@micropowerdirect.com




MicroPower Direct Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com