Page 1 - MPD MPM-30CM Datasheet
P. 1





MPM-30CM Series



Chassis Mount, 30W


Single, Dual & Triple Out

AC/DC Power Supplies



Electrical Specifi cations
Key Features: Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Input
• 30W Output Power
Parameter Conditions Min. Typ. Max. Units
• Universal 85-265 VAC Input Input Voltage Range 85 265 VAC
• EN 60950 Approved (UL) Input Frequency 47 440 Hz
Input Current See Model Selection Guide
• Single, Dual & Triple Outputs 115 VAC 20.0
Inrush Current A Pk
• Meets EN 55022 B 230 VAC 40.0
EMI Meets CISPR Pub. 22/FCC Class B
• Meets IEC Safety Class II
Output
• Chassis Mount Case Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
PCB Mount Models Output Current See Model Selection Guide
& DIN Rail Mount Output Voltage Accuracy, Note 1 ±1.0 ±2.0 %
Option Available! Line Regulation VIN = Min to Max ±0.2 ±1.0 %
Load Regulation, Single Output IO = Min to Max ±0.5 ±1.0 %
Load Regulation, Dual Output IO = Min to Max ±2.5 ±5.0 %
Load Regulation, Triple Output - Primary IO = Min to Max ±2.5 ±5.0 %
Load Regulation, Triple Output - Aux. IO = Min to Max ±4.0 %
3.3 & 5.0 VDC Output 1.5 1.8
Ripple & Noise (20 MHz) %VP-P of VO
All Other Outputs 1.0 1.3
Hold-Up Time 115 VAC, 60 Hz 20 mSec
Temperature Coeffi cient ±0.02 %/°C
Over Voltage Protection Zener Diode Clamp 120 % of VO
Short Circuit Protection, Note 4 Continuous (Autorecovery)
Overload Protection, Note 5 Typ. 120% to 180% of Output Power
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage Input to Output 3,000 VAC
Isolation Test Voltage Input to Output, Flash Tested For 60S 4,700 VAC
Isolation Resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) EN 61000-4-2 Level B
RF Field Susceptibility EN 61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV
Surge EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency 100 kHz
Environmental
Parameter Conditions Min. Typ. Max. Units
Operating Temperature Range Ambient -25 +25 +71 °C
MicroPower Direct Storage Temperature Range -40 +85 °C
292 Page Street Cooling Free Air Convection (See Derating Curve)
Suite D Humidity RH, Non-condensing 95 %
Stoughton, MA 02072
Physical
USA
Case Size, Chassis Mount 4.41 x 2.51 x 1.01 Inches (112.0 x 63.8 x 25.6 mm)
Case Size, DIN Rail Option 4.41 x 2.51 x 1.44 Inches (112.0 x 63.8 x 36.6 mm)
T: (781) 344-8226
F: (781) 344-8481 Case Material Non-Conductive Plastic& Fiberglass (UL94-V0)
E: sales@micropowerdirect.com Weight 6.72 Oz (191g)
W: www.micropowerdirect.com Reliability Specifi cations
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 250 kHours
Safety Standards UL 60950, EN 60950
Safety Approvals UL, cUL; File No. E245422
Safety Class IEC 61140 Class II
www.micropowerdirect.com
   1   2