Page 2 - MPD MPM-25S Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Over Volt. Notes:
Model Effi ciency 1. Operation at no load will not damage the units, however, they may not meet
Number Current (A) Voltage Current (A) Protection (%, Typ) all specifi cations.
115 VAC 230 VAC (VDC) Max Min (VDC) 2. Load regulation is measured for an output change of 10% to 100% at nominal
input line.
MPM-25S-03 0.42 0.23 3.3 4.10 0.0 7.5 73 3. All units are rated for EN 55022 (CE/RE) class B without external components.
MPM-25S-05 0.42 0.23 5.0 4.10 0.0 7.5 74 4. All units are rated for EN 61000-4-4 (±2 kV) without external components. They
MPM-25S-09 0.42 0.23 9.0 2.50 0.0 12.0 78 will meet EN 61000-4-4 (±4 kV) with additional input fi ltering as shown below.
MPM-25S-12 0.42 0.23 12.0 2.10 0.0 20.0 82 5. All units are rated for EN 61000-4-5 (±1 kV/±2 kV) without external components.
They will meet EN 61000-4-5 (±2 kV/±4 kV) with additional input fi ltering as shown
MPM-25S-15 0.42 0.23 15.0 1.60 0.0 20.0 83
below.
MPM-25S-24 0.42 0.23 24.0 1.10 0.0 30.0 85 6. It is recommended that a fuse be used on the input of a power supply for protection.
MPM-25S-48 0.42 0.23 48.0 0.50 0.0 60.0 87 For the MPM-25S series, a 3.15A/250 VAC slow blow should be used.
Typical Connection The diagram below illustrates a typical application connection of the MPM-25S-xx series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 3.15A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is required on the input to protect the unit in the event of a surge.
A 561KD14 or equivalent is recommended.
3. A simple external circuit may be used to adjust the output ±10%. To adjust the
output DOWN, connect a 5%, 3W resistor between the plus output pin and the
VOUT trim pin. To adjust the output UP, connect a 5%, 3W resistor between the
minus output pin and the VOUT trim. Contact the factory for resistor values needed
to achieve a specifi c output.
4. Recommended output fi ltering capacitors are:
C1 C2 TVS
MPM-25S-03 330 µF/16V 0.01 µF/25V SMBJ7.0A
MPM-25S-05 330 µF/16V 0.01 µF/25V SMBJ7.0A
MPM-25S-09 330 µF/25V 0.01 µF/25V SMBJ12A
Typical Connection: With ACFM-01 Input Module (See note 5) MPM-25S-12 330 µF/25V 0.01 µF/25V SMBJ20A
MPM-25S-15 330 µF/25V 0.01 µF/25V SMBJ20A
MPM-25S-24 120 µF/25V 0.01 µF/25V SMBJ30A
MPM-25S-48 60 µF/25V 0.01 µF/25V SMBJ60A

Output capacitor (C2) is a high frequency, low resistance electrolytic capacitor.
Capacitor (C1) is ceramic. Voltage derating of capacitors should be >80%.
5. Input noise and surge suppression modules are available for a number of MPD
AC/DC power supplies. An MPM-25S-xx connection with the ACFM-01 is il-
lustrated in the diagram at left. For pricing or full technical information on these
modules (ACFM-01 and ACFM-02) please contact the factory.
Pin Connections
Pin Function Pin Function
Derating Curve 1 AC-Ground 4 -Vout
2 AC-Neutral 8 +Vout
Mechanical Dimensions 3 AC-Line Trim Trim














Input Voltage Vs Load















Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct The MPM-25-xx series is also available with
a chassis mount or DIN mount adapter.
Contact the factory for more information
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com