Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3)
Capacitive
Model Current (A) Current (A) Current (A) Current (A) Effi ciency
Number Voltage Voltage Voltage Load (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (VDC) Max. Min. (VDC) Max. Min. (µF, Max)
MPM-15S-05CM 0.290 0.14 5.0 3.000 0.300 3,900 75
MPM-15S-12CM 0.275 0.14 12.0 1.250 0.125 2,200 79
MPM-15S-15CM 0.275 0.14 15.0 1.000 0.100 2,200 79
MPM-15S-24CM 0.275 0.14 24.0 0.625 0.063 2,200 79
MPM-15S-48CM 0.273 0.14 48.0 0.310 0.030 1,000 79
MPM-15D-12CM 0.275 0.14 +12.0 +0.625 +0.063 -12.0 -0.625 -0.063 ±1,500 79
MPM-15D-15CM 0.275 0.14 +15.0 +0.500 +0.050 -15.0 -0.500 -0.050 ±1,500 79
MPM-15T-0512CM 0.290 0.14 5.0 2.000 +0.200 +12.0 +0.200 +0.020 -12.0 -0.200 -0.020 Note 5 74
MPM-15T-0515CM 0.284 0.14 5.0 1.80 +0.200 +15.0 +0.150 +0.015 -15.0 -0.150 -0.015 Note 5 74
Other output combinations are available Derating Curve
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. Load regulation is measured for an output change of 0% to 100% at nominal input
line. For multiple output models, the loads are balanced.
2. Operation at no-load will not damage these units. However, they may not meet all
specifi cations.
3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers
automatically when the fault condition is removed.
4. Output overload protection is provided by a fold back current limiting circuit.
5. For triple output models, the maximum capacitive load for 5 VDC outputs is 2,200
µF. For all other outputs it is ±1,500 µF.
6. The MPM-15CM series includes a built-in 2.0A/250 VAC fuse. It is recommended
that an external 1.5A slow blow fuse also be used on the input for protection.





Mechanical Dimensions, Chassis Mount
Pin Connections
Pin Single Dual Triple
1 AC-Neutral
2 AC-Line
3NC NC -Vo 3
4 -Vo -Vo Common 2/3
5 NC Common +Vo 2
6 +Vo +Vo -Vo 1
7NC NC +Vo 1
NC = No Connection



Model Number












A DIN Rail mounting kit is available
Contact the factory for details at:
sales@micropowerdirect.com



Notes:
• All dimensions are typical in inches (mm)
MicroPower Direct • Tolerance x.xx = ±0.01 (±0.25)