Page 2 - MPD MPM-10 Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output 1 (Vout 1) Output 2 (Vout 2)
Model Current (A) Current (A) Over Volt. Current (A) Over Volt. Effi ciency
Number Voltage Protection Voltage Protection (%, Typ)
(VDC) Load (VDC) Load
115 VAC 230 VAC Rated (VDC) Rated (VDC)
Reg. Reg.
MPM-10S-03 0.23 0.12 3.3 2.00 ±1.0% 6.5 70
MPM-10S-05 0.23 0.12 5.0 2.00 ±1.0% 6.5 76
MPM-10S-09 0.23 0.12 9.0 1.10 ±1.0% 12.0 78
MPM-10S-12 0.23 0.12 12.0 0.90 ±1.0% 20.0 80
MPM-10S-15 0.23 0.12 15.0 0.70 ±1.0% 20.0 81
MPM-10S-24 0.23 0.12 24.0 0.45 ±1.0% 30.0 82
MPM-10D-05 0.23 0.12 +5.0 +1.00 ±2.0% 6.5 -5.0 -1.00 ±2.0% 6.5 76
MPM-10D-12 0.23 0.12 +12.0 +0.45 ±2.0% 20.0 -12.0 -0.45 ±2.0% 20.0 80
MPM-10D-15 0.23 0.12 +15.0 +0.35 ±2.0% 20.0 -15.0 -0.35 ±2.0% 20.0 81
MPM-10D-24 0.23 0.12 +24.0 +0.20 ±2.0% 30.0 -24.0 -0.20 ±2.0% 30.0 84
MPM-10ID-0505 0.23 0.12 5.0 1.80 ±3.0% 6.5 5.0 0.20 ±5.0% 6.5 75
MPM-10ID-0512 0.23 0.12 5.0 1.50 ±3.0% 6.5 12.0 0.20 ±5.0% 20.0 79
MPM-10ID-0515 0.23 0.12 5.0 1.40 ±3.0% 6.5 15.0 0.20 ±5.0% 20.0 79
MPM-10ID-0524 0.23 0.12 5.0 1.00 ±3.0% 6.5 24.0 0.20 ±5.0% 30.0 81
Notes: Typical Connection
1. Load regulation is measured for an output change of 10% to 90% at
nominal input line. For multiple output models, the loads are balanced.
2. The MPM-10 series is specifi ed for operation over the wide oper-
ating temperature range of -25°C to +55°C without derating. For
operation over +55°C, derate the power linearly by 3.75%/°C from
+55°C to +70°C.
3. Model numbers MPM-10ID-05xx are dual isolated units (Dual
ISO). The outputs on these models are isolated from each other.
4. It is recommended that a fuse be used on the input of a power supply
for protection. For the MPM-10 series, a 2A/250 VAC slow blow
should be used.


Mechanical Dimensions











Typical Component Values
Vout C1, C3 C2, C4 Fuse TVS
3.3 330 ~ 1,000 µF/16V P6KE6.8A
5.0 330 ~ 1,000 µF/16V 2A/ P6KE6.8A
0.1 µF/50V
12.0 220 µF/25V 250 VAC P6KE16A
Ceramic
15.0 220 µF/25V Slow Blow P6KE20A
24.0 120 µF/35V P6KE33A
Notes:
1. C1 and C3 are high frequency, low resistance electrolytic capacitors. Refer to the suppliers
specifi cations for capacitance/current ratings.
2. Voltage derating on all capacitors should be 80% or higher.
3. C2 and C4 eliminate high frequency noise.
4. The TVS is recommended to protect load circuitry in the event of a module failure.
Pin Connections
Pin Single Dual Dual ISO
1 AC-Ground AC-Ground AC-Ground
2 AC-Neutral AC-Neutral AC-Neutral
3 AC-Line AC-Line AC-Line
4 -Vo 1 -Vo 2 -Vo 1
5 No Pin No Pin +Vo 1
Notes: 6 No Pin Common No Pin
• All dimensions are typical in inches (mm) 7 No Pin No Pin -Vo 2
• Tolerance x.xx = ±0.01 (±0.25)
8 +Vo 1 +Vo 1 +Vo 2
MicroPower Direct


We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com