Page 2 - MPD MPM-10PB Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Maximum Maximum
Model Capacitive Output Effi ciency
Current (A) Current
Number Voltage Load Power (%, Typ)
115 VAC 230 VAC (VDC) Max. (A) Min. (%) (µF) (W)
MPM-10S-03PB 0.171 0.128 3.3 2.500 10.0 2,200 8.25 70
MPM-10S-05PB 0.201 0.151 5.0 2.000 10.0 2,200 10.00 72
MPM-10S-12PB 0.191 0.143 12.0 0.833 10.0 1,000 10.00 76
MPM-10S-15PB 0.193 0.145 15.0 0.667 10.0 1,000 10.00 75
MPM-10S-24PB 0.201 0.151 24.0 0.417 10.0 680 10.00 72
Notes: Derating Curve
1. Ripple and noise are measured at 20 Mhz
bandwidth with a 0.1µF and a 47 µF capacitor
connected in parallel as close to the unit output
terminals as possible.
2. Output short circuit protection is provided by a “hiccup
mode” circuit. The unit recovers automatically when
the fault condition is removed.
3. Operation at under no load conditions will not damage
these units.
4. It is recommended that a fuse be used on the
input of a power supply for protection. For the
MPM-10PB series, a 1.5A/250 VAC slow blow
should be used.













Mechanical Dimensions

























Pin Connections
Pin Function
1 AC-Neutral
2 AC-Line
3 +Vout
4 -Vout




Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.5)
MicroPower Direct


We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com