Model Selection Guide www.micropowerdirect.com
Input Output 1 (Vout 1) Output 2 (Vout 2)
Model Current (A) Current (A) Current (A) Capacitive Effi ciency
Number Voltage Voltage Load (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (VDC) Max. Min. (µF, Max)
MPM-10S-03IS 0.137 0.075 3.3 2.000 0.200 3,900 70
MPM-10S-05IS 0.199 0.075 5.0 2.000 0.200 3,300 73
MPM-10S-12IS 0.191 0.075 12.0 0.833 0.083 2,200 76
MPM-10S-15IS 0.191 0.075 15.0 0.666 0.066 2,200 76
MPM-10S-24IS 0.190 0.075 24.0 0.416 0.042 1,000 76
MPM-10D-12IS 0.172 0.075 +12.0 +0.380 +0.038 -12.0 -0.380 -0.038 ±1,000 77
MPM-10D-15IS 0.169 0.075 +15.0 +0.300 +0.030 -15.0 -0.300 -0.030 ±1,000 77

Other output combinations are available Derating Curve
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. Load regulation is measured for an output change of 0% to 100% at
nominal input line. For multiple output models, the loads are balanced.
2. Operation at no-load will not damage these units. However, they may
not meet all specifi cations.
3. Output short circuit protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is removed.
4. Output overload protection is provided by a fold back current limiting
circuit.
5. The MPM-10IS series includes a built-in 2A/250 VAC fuse. It is recom-
mended that an external 1.5A slow blow fuse also be used on the input
for protection.






Model Number
Mechanical Dimensions












Pin Connections
Pin Single Dual
1 AC-Neutral AC-Neutral
2 AC-Line AC-Line
3 -Vo -Vo
4 NC Common
5 +Vo +Vo
NP = No Connection




Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)



MicroPower Direct


We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com