Page 2 - MPD MPM-07PB Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output 1 (Vout 1) Fuse
Capacitive
Model Current (A) Current (A) Effi ciency Rating
Load
Number Voltage (%, Typ) (µF Max) Slow-Blow
115 VAC 230 VAC (VDC) Max. Min. (mA)
MPM-07S-03PB 0.96 0.051 3.3 1.400 0.140 70 2,200 1,500
MPM-07S-05PB 0.139 0.051 5.0 1.400 0.140 73 2,200 1,500
MPM-07S-12PB 0.130 0.051 12.0 0.583 0.058 78 1,000 1,500
MPM-07S-15PB 0.130 0.051 15.0 0.466 0.047 78 1,000 1,500
MPM-07S-24PB 0.130 0.051 24.0 0.291 0.029 78 680 1,500
Other outputs may be available Derating Curve
Contact the factory for details at:
sales@micropowerdirect.com
Notes:
1. Load regulation is measured for an output change of 0% to 100% at
nominal input line.
2. Operation at no-load will not damage these units. However, they may
not meet all specifi cations.
3. Output short circuit protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is removed.
4. Output overload protection is provided by a fold back current limit-
ing circuit.
5. It is recommended that an external slow blow fuse also be used on
the input for protection. See the table above for the correct rating.





Mechanical Dimensions













Pin Connections
Pin Function
1 AC-Neutral
2 AC-Line
3 +Vout
4 -Vout























MicroPower Direct Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com