Page 2 - MPD MPM-05MM Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output
Current Capacitive Fuse
Model (mA Typ) Current (mA) Effi ciency Rating
Load
Number Voltage (%, Typ) (µF Max) Slow-Blow
115 VAC (VDC) Max. Min. Peak (mA) Other outputs may be available
Contact the factory for details at:
MPM-05S-03MM (C) 117 3.3 1,515 0.0 1,970 74 2,200 1,000
sales@micropowerdirect.com
MPM-05S-05MM (C) 108 5.0 1,000 0.0 1,300 80 1,000 1,000
MPM-05S-09MM (C) 106 9.0 555 0.0 721 82 300 1,000
MPM-05S-12MM (C) 106 12.0 416 0.0 540 82 160 1,000
MPM-05S-15MM (C) 104 15.0 333 0.0 433 83 100 1,000
MPM-05S-24MM (C) 104 24.0 208 0.0 270 83 43 1,000
MPM-05S-48MM (C) 102 48.0 104 0.0 135 85 10 1,000
Notes: Derating Curve
1. Inrush current is given for a cold start at 25°C.
2. No load power consumption meets the standby power consumption limits in
the European ERP Directive 2009/125/EC.
3. Ripple & Noise is specifi ed over a range of 0 - 20 MHz. It is measured with a
1 µF/50V MLCC connected from +VOUT to -VOUT.
4. Over voltage protection is provided by a zener diode clamp.
5. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
6. Output overload protection is provided by a fold back current limiting circuit
with auto-recovery. A long-term overload could damage the unit.
7. Operation at no-load will not damage these units. However, they may not meet
all specifi cations.
8. Peak load is specifi ed as lasting <30s with a maximum duty cycle of 10%
The average power should not exceed the maximum power rating.
9. It is recommended that an external slow blow fuse also be used on the input
for protection. See the table above for the correct rating.

Mechanical Dimensions
Board Mount Chassis Mount







Pin Connections
Pin Function
1 AC-Neutral
2 AC-Line
3 No Connection
4-VOUT
5+VOUT





















To order a chassis mount version, add a “C” to the model number
(i.e. MPM-05S-15MMC)
MicroPower Direct Notes:

• All dimensions are typical in inches (mm)
We Power Your Success - For Less! • Tolerance x.xx = ±0.02 (±0.25)
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
   1   2