Page 2 - MPD MPM-04V Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output 1 (See Note 1) Output 2 (See Note 1) Maximum
Model Output Effi ciency
Current (A) Current (mA) Maximum Current (mA) Maximum
Number Voltage Cap. Load Voltage Cap. Load Power (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (µF) (VDC) Max. Min. (µF) (W)
MPM-04SV-03 0.075 0.055 3.3 1.200 0.0 14,000 3.96 70
MPM-04SV-05 0.075 0.055 5.0 800 0.0 8,000 4.0 72
MPM-04SV-08 0.075 0.055 8.0 500 0.0 2,700 4.0 74
MPM-04SV-09 0.075 0.055 9.0 444 0.0 2,400 4.0 75
MPM-04SV-12 0.075 0.055 12.0 333 0.0 1,000 4.0 76
MPM-04SV-14 0.075 0.055 14.0 286 0.0 750 4.0 76
MPM-04SV-15 0.075 0.055 15.0 267 0.0 700 4.0 76
MPM-04SV-24 0.075 0.055 24.0 167 0.0 220 4.0 77
MPM-04DV-0503 0.085 0.065 +5.0 +600 0.0 5,600 +3.3 +150 0.0 4,700 3.5 72
MPM-04DV-0805 0.085 0.065 +8.0 +375 0.0 1,000 +5.0 +120 0.0 4,700 3.6 74
MPM-04DV-1205 0.085 0.065 +12.0 +250 0.0 330 +5.0 +120 1.2 4,700 3.6 75
Notes:
1. For dual output models, Output 1 is +Vo and Output 2 is +Vr. A Mechanical Dimensions
47 µF/25V ceramic capacitor must be connected from +Vo (pin 12)
of dual output models to Common (pin 11). Without this capacitor, the
unit may not meet all specifi cations.
2. For dual output models, output voltage accuracy is specifi ed as ±2%
for +Vo and ±5% for +Vr.
3. For dual output models, line regulation is specifi ed as ±0.2% for +Vo
and ±3% for +Vr.
4. Output short circuit protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is removed.
5. Operation at under no load conditions will not damage these units.
It is recommended that the minimum load values in the table above
be used.
6. It is recommended that a fuse be used on the input of a power
supply for protection. For the MPM-04V series, a 3.15A/250
VAC slow blow should be used.












Pin Connections
Pin Single Dual Pin Single Dual
1NC NC 10NC +Vr
7 AC-Neutral 11 -Vo Common
9 AC-Line 12 +Vo +Vo
NC = No Connection Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Derating Curve, Vin = 90-280 VAC Derating Curve, Vin = 280-305 VAC



















MicroPower Direct


We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
   1   2