Page 1 - MPD MPM-04V Datasheet
P. 1





MPM-04V Series



Compact, Board Mount 4W


Ultra-Wide Input Range

AC/DC Power Supplies




Key Features: Electrical Specifi cations
Specifi cations typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
• 4W Output Power
Input
• Universal 90-305 VAC Input
Parameter Conditions Min. Typ. Max. Units
• Miniature Size 90 305 VAC
Input Voltage Range
• EN 60950 Approved (UL) 120 430 VDC
• Meets IEC Safety Class II Input Frequency 47 440 Hz
Input Current See Model Selection Guide
• Single and Dual Outputs 115 VAC 15.0
• Meets EN 55022 B Inrush Current 230 VAC 25.0 A Pk
• >350 kHour MTBF EMI Meets CISPR Pub. 22/FCC Class B
EMC Meets EN 55024
Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Accuracy See Note 2 ±2.0 %
3.3V Output, VIN = Min to Max ±0.5
Line Regulation, See Note 3 %
5V to 24V Output, VIN = Min to Max ±0.2
Load Regulation, Single Output 3.3V output, IO = 0% to 100% ±1.5 %
Load Regulation, Single Output 5V to 24V output, IO = 0% to 100% ±0.5 %
Load Regulation, Dual Output Vout 1, IO = 10% to 100% ±0.5 %
Load Regulation, Dual Output Vout 2, IO = 10% to 100% ±5.0 %
Single 3.3V & 5V Outputs 150.0
Ripple/Noise (20 MHz) mVP-P
All Other Models 100.0
Hold-Up Time 115 VAC 15 mSec
Temperature Coeffi cient ±0.02 %/°C
Over Voltage Protection Zener Diode Clamp 120 % of VO
Short Circuit Protection, See Note 4 Continuous (Autorecovery)
Overload Protection 105 120 % of IO
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage Input to Output 3,000 VAC
Isolation Resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) EN 61000-4-2 Level B
RF Field Susceptibility EN 61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains EN 61000-4-4 Level 3 2 kV
Surge EN 61000-4-5 Level 3 1kV/2 kV
Switching Frequency 132 kHz
Environmental
MicroPower Direct Parameter Conditions Min. Typ. Max. Units
292 Page Street Operating Temperature Range Ambient -40 +25 +70 °C
Suite D Storage Temperature Range -40 +125 °C
Stoughton, MA 02072 Cooling Free Air Convection (See Derating Curve)
USA Humidity RH, Non-condensing 95 %
Physical
T: (781) 344-8226 Case Size 1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm)
F: (781) 344-8481 Case Material Non-Conductive Plastic & Fiberglass (UL94-V0)
E: sales@micropowerdirect.com Weight 0.91 Oz (26g)
W: www.micropowerdirect.com Reliability Specifi cations
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 350 kHours
Safety Standards UL 60950, EN 60950
Safety Approvals UL, cUL; File No. E245422
Safety Class IEC 61140 Class II
www.micropowerdirect.com