Page 2 - MPD MPM-04E Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output 1 Output 2
Model Effi ciency
Current (A) Current (mA) Maximum Current (mA) Maximum
Number Voltage Cap. Load Voltage Cap. Load (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (µF) (VDC) Max. Min. (µF)
MPM-04S-03E 0.082 0.065 3.3 1.200 0.0 14,000 70
MPM-04S-05E 0.082 0.065 5.0 800 0.0 8,000 72
MPM-04S-09E 0.077 0.065 9.0 444 0.0 2,400 75
MPM-04S-12E 0.076 0.065 12.0 333 0.0 1,000 76
MPM-04S-15E 0.076 0.065 15.0 267 0.0 700 76
MPM-04S-24E 0.076 0.065 24.0 167 0.0 220 77
MPM-04D-12E 0.076 0.065 +12.0 +166 0.0 330 -12.0 -166 0.0 330 77
MPM-04D-15E 0.076 0.065 +15.0 +133 0.0 260 -15.0 -133 0.0 260 77
MPM-04D-0503E 0.072 0.065 +5.0 +600 150.0 5,600 +3.3 +150 37.5 4,700 72
MPM-04D-1205E 0.072 0.065 +12.0 +250 62.5 330 +5.0 +120 30.0 4,700 75

Notes:
1. For models, MPM-04D-0503E and MPM-04D-1205E output Mechanical Dimensions
voltage accuracy is specifi ed as ±2% typical and ±5% Max.
2. For models, MPM-04D-0503E and MPM-04D-1205E line
regulation is specifi ed as ±0.5% typical/±1.0% Max for VO1 and
±1.0% typical/±3.0% Max for VO2.
2. For models, MPM-04D-0503E and MPM-04D-1205E load
regulation is specifi ed as ±0.5% typical/±1.0% Max for VO1 and
±2.5% typical/±5.0% Max for VO2.
4. Output short circuit protection is provided by a “hiccup mode”
circuit. The unit recovers automatically when the fault condition
is removed.
5. Overload protection is provided by a foldback circuit. Extended
operation under an overload condition could damage the unit.
6. Operation at under no load conditions will not damage these units.
It is recommended that the minimum load values in the table above
be used.
6. It is recommended that a fuse be used on the input of a
power supply for protection. For the MPM-04E series, a
1A/250 VAC slow blow should be used.












Notes:
Derating Curve • All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)


Pin Connections
Pin Single Dual (±) Dual (Sep)
1NC
2NC
3+VOUT +VOUT +VOUT1
4-VOUT Common Common
5NP -VOUT +VOUT2
6 AC-Neutral
7 AC-Line
NC = No Connection
NP = No Pin









MicroPower Direct


We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com