Page 2 - MPD MPM-03MM Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output
Current Capacitive Fuse
Model (mA Typ) Current (mA) Effi ciency Rating
Number Voltage (%, Typ) Load Slow-Blow
(VDC) (µF Max) Other outputs may be available
115 VAC Max. Min. Peak (mA)
Contact the factory for details at:
MPM-03S-03MM 62 3.3 900 0.0 1,170 70 1,200 1,000 sales@micropowerdirect.com
MPM-03S-05MM 61 5.0 600 0.0 780 72 820 1,000
MPM-03S-09MM 57 9.0 333 0.0 430 77 470 1,000
MPM-03S-12MM 56 12.0 250 0.0 320 78 330 1,000
MPM-03S-15MM 56 15.0 200 0.0 260 78 270 1,000
MPM-03S-24MM 56 24.0 125 0.0 160 78 180 1,000
Notes: Derating Curve
1. Inrush current is given for a cold start at 25°C.
2. No load power consumption meets the standby power consumption limits in
the European ERP Directive 2009/125/EC.
3. Over voltage protection is provided by a zener diode clamp.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit
with auto-recovery. A long-term overload could damage the unit.
6. Operation at no-load will not damage these units. However, they may not meet
all specifi cations.
7. Peak load is specifi ed as lasting <30s with a maximum duty cycle of 10%
The average power should not exceed the maximum power rating.
8. It is recommended that an external slow blow fuse also be used on the input
for protection. See the table above for the correct rating.



Mechanical Dimensions






















Pin Connections
Pin Function
1 AC-Neutral
2 AC-Line
3 No Connection
4-V
OUT
5+VOUT


Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.25)






MicroPower Direct


We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
   1   2