Model Selection Guide www.micropowerdirect.com
Input Output Maximum Output
Model Output Voltage Capacitive Effi ciency Fuse Rating
Load
Number Current (A Max.) Voltage Current Current Power Accuracy (µF, Max) (%, Typ) Slow-Blow
115 VAC 277 VAC (VDC) (mA Max.) (mA Min.) (W) (%)
MPL-01S-05EUP(F) 0.120 0.060 5.0 200 0.0. 1.0 ±8.0 220 66 1.0A/300 VAC
MPL-01S-09EUP(F) 0.120 0.060 9.0 111 0.0 1.0 ±5.0 100 67 1.0A/300 VAC
MPL-01S-12EUP(F) 0.120 0.060 12.0 83 0.0 1.0 ±5.0 100 70 1.0A/300 VAC
MPL-01S-15EUP(F) 0.120 0.060 15.0 67 0.0 1.0 ±5.0 100 69 1.0A/300 VAC
MPL-01S-24EUP(F) 0.120 0.060 24.0 42 0.0 1.0 ±5.0 100 68 1.0A/300 VAC
Notes: from MPD. The model MACFM-03D is recommended. Contact the factory for more information.
1. All units operate over the full input voltage range and the specifi ed operating temperature range with 6. All units will meet the requirements of EN 61000-4-5 (±1 kV/±2 kV), with the input circuit shown in the
no derating. “Typical Connection 1,2” diagrams below. This fi ltering may be added discretely, or by using a fi lter module
2. The external fi lter components (C1, C2, C3 and LOUT) shown in the typical connection diagrams below (MACFM-03D) from MPD. Contact the factory for more information.
are required to meet specifi ed operation. 7. All units will meet the requirements of EN 61000-4-6 (10V rms), with the input circuit shown in the
3. All units will meet EN 55022 (CE/RE) class A with the input circuit shown in the “Typical Connection 1” diagram “Typical Connection 2” diagram below. This fi ltering may be added discretely, or by using a fi lter
below. The MPL01SEUP will meet class B with the additional fi ltering shown in the “Typical Connection 2” module (MACFM-03D) from MPD. Contact the factory for more information.
diagram below. MPD offers fi lter modules that will save on board space and make the input fi lter design easier. 8. Operation at no load will not damage the units, however, they may not meet all specifi cations.
The model MACFM-03D is recommended. Contact the factory for more information. 9. The MPL-01SEUP series will make an audible noise when operated under light load conditions.
4. To meet the requirements of EN 61000-4-3, (10V/m) external fi ltering (as shown in the “Typical Connection This does not effect the product operation or reliability.
2” diagram below) is required. This fi ltering may be added discretely, or by using a fi lter module from MPD. 10. It is always recommended that a fuse be used on the input of a power supply for protection. For the
The model MACFM-03D is recommended. Contact the factory for more information. MPL-01SEUP series, a 1.0A/300 VAC slow blow should be used.
5. All units will meet EN 61000-4-4 (±2 kV) with the input circuit shown in the “Typical Connection 1” diagram 11. The MPL-01SEUP series is available with the pins factory set to a 90° angle (see mechanical
below. To meet the requirements of EN 61000-4-4 (±4 kV), external components (as shown in the “Typical diagrams on page 3). To order units with the modifi ed pins, just add an “F” to the product model
Connection 2” diagram below) are required. This fi ltering may be added discretely, or by using a fi lter module number (i.e. MPL-01S-12EUPF).
Typical Connection 1















The diagram above illustrates a typical connection of the MPL-01SEUP series. With this connection, the unit will meet EN 55022 class A, EN 61000-4-2 (±4kV), EN61000-4-4 (±2kV), and EN 61000-4-11. Components C1 and
C3 are required to meet specifi ed operation limits. The recommended input components are a 15D-5 (NTC), S14k350 (MOV1) and 1 mH (LIN). The recommended output component values are given in the table below.
Typical Connection 2: With External EMC Components















For applications that require meeting higher EMC standards, the circuit shown above is recommended. Some notes operation. Low ESR, high frequency electrolytic capacitors should be used. The recommended values
on this diagram (starting with the input circuit) are: are given in the table below.
1. It is recommended that an external fuse be used. The recommended fuse is 1A/300V. 5. The output TVS will help protect system circuitry if power supply fails. A recommended value is given
2. The capacitors CX and CYx are “safety” capacitors. in the table below.
3. Capacitor C1 is a fi lter component. This capacitor is required to meet specifi ed operation. It should 6. Capacitor C4 is ceramic. This capacitor is used to fi lter high frequency noise. A recommended value
be a high frequency, low ESR electrolytic capacitor. The recommended value is given in the table is given in the table below.
below. 7. All of the components within the dotted lines of the input EMC circuit are included in the MACFM-03D,
4. Capacitors C2 and C3 and inductor LOUT are output fi lter components. They are required to meet specifi ed a fi lter module available from MPD. Please contact the factory for more information.
Recommended values for components are:
External Components
Model
Number MOV LCM Cx LDM CY1/CY2/CY3 R1/R2 C1 C2 LOUT C3 C4 TVS
(Required) (Required) (Required) (Required)
MPL-01S-05EUP 100 F/16V SMBJ7.0A
MPL-01S-09EUP 150 F/35V SMBJ12A
MPL-01S-12EUP S14k350 3.5 mH 0.1 F/275 VAC 0.33 mH 1 nF/400 VAC 33ม/3W 4.7 F/400V 2.2 H 68 F/35V 0.1 F/50V
SMBJ20A
MPL-01S-15EUP 100 F/35V
MPL-01S-24EUP SMBJ30A