Page 3 - MPD MB5000RU Datasheet
P. 3



www.micropowerdirect.comww.micropowerdirect.com.micropowerdirect.com
Derating Curves w www
MB50xxS-03RU Without Heatsink MB50xxS-03RU With Heatsink















MB50xxS-12RU, -15RU Without Heatsink MB50xxS-12RU, -15RU With Heatsink
















MB50xxS-05RU, -24RU Without Heatsink MB50xxS-05RU, -24RU With Heatsink


















EMC Specifi cations
Parameter Standard External Component Connection
Radiated Emissions EN 55022 Class A/B
Conducted Emissions EN 55022 Class A/B
ESD EN 61000-4-2 Criteria B; ±8 kV Air, ±6 kV Contact
RS EN 61000-4-3 Criteria A; 10V/m
EFT, See Notes EN 61000-4-4 Criteria A; ±2 kV
Surge, See Notes EN 61000-4-5 Criteria A; ±1 kV
CS EN 61000-4-6 Criteria A; 10 V/m

Notes:
All units should meet EN 55022 (CE/RE) class A/B with the simple external circuit shown at right. To
meet the requirements of EN 61000-4-4 and EN 61000-4-5, the value of C1 should be changed to
220 µF/100V. Contact the factory for more information.


Standard Model C1 C2 L1 L2 C3 C4 C5
MB5024S-xxRU 10 µF/50V 1210 X7S --- 1.5 µH --- --- --- 1,000 pF/2kV 1206 MLCC
EN55022 Class A
MB5048S-xxRU 3.3 µF/100V 1210 X7S --- 6.8 µH --- --- --- 1,000 pF/2kV 1206 MLCC
MB5024S-xxRU 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S --- 1 mH 3.3 µF/100V 1210/X7S 1,200 pF/2kV 1808 X7R 1,200 pF/2kV 1808 X7R
EN55022 Class B
MB5048S-xxRU 3.3 µF/100V 1210/X7S 3.3 µF/100V 1210/X7S --- 1 mH 3.3 µF/100V 1210/X7S 1,200 pF/2kV 1808 X7R 1,200 pF/2kV 1808 X7R




MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
   1   2   3   4