Page 2 - MPD MB5000RU Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Refl ected Output Over
Model Ripple Voltage Effi ciency Capacitive Fuse Rating
Load
Number Voltage (VDC) Current (mA) Current Voltage Current Current Protection (%, Typ) (µF Max) Slow-Blow
(A)
Nominal Range Full-Load No-Load (mA, Typ) (VDC) (mA, Max) (mA, Min) (VDC)
MB5024S-03RU 24 9.0 - 36.0 1,528 80 40 3.3 10,000 0.0 3.9 90 26,000 10.0
MB5024S-05RU 24 9.0 - 36.0 2,290 60 40 5.0 10,000 0.0 6.2 91 17,000 10.0
MB5024S-12RU 24 9.0 - 36.0 2,267 80 40 12.0 4,170 0.0 15.0 92 3,000 10.0
MB5024S-15RU 24 9.0 - 36.0 2,263 80 40 15.0 3,330 0.0 18.0 92 2,000 10.0
MB5024S-24RU 24 9.0 - 36.0 2,286 80 40 24.0 2,080 0.0 30.0 91 750 10.0
MB5048S-03RU 48 18.0 - 75.0 764 40 30 3.3 10,000 0.0 3.9 90 26,000 5.0
MB5048S-05RU 48 18.0 - 75.0 1,145 30 30 5.0 10,000 0.0 6.2 91 17,000 5.0
MB5048S-12RU 48 18.0 - 75.0 1,134 60 30 12.0 4,170 0.0 15.0 92 3,000 5.0
MB5048S-15RU 48 18.0 - 75.0 1,134 60 30 15.0 3,330 0.0 18.0 92 2,000 5.0
MB5048S-24RU 48 18.0 - 75.0 1,143 50 30 24.0 2,080 0.0 30.0 91 750 5.0
For heatsink option, add suffi x “H” to model number (i.e. MB5024S-03RU-H) Remote On/Off
Notes:
1. Start up time is measured at nominal input and with a constant resistive load. Applying a signal to pin 3 will turn the unit ON/OFF. If the pin is left open, the unit operates. If
2. Load regulation is specifi ed for a load change of minimum load to full load. grounded, the unit will shut off. The specifi cations for the ON/OFF function are:
3. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be Parameter Min Typ Max Units
connected in parallel from the +VOUT to the -VOUT pins. Supply On 3.5 12.0 VDC
4. Transient recovery is measured to within a 1% error band for a load step change of 25%. Supply Off 0.0 1.2 VDC
5. Short circuit protection is provided by a “hiccup mode” circuit.
6. Operation at no-load will not damage the unit. Standby Input Current 2.5 mA
7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selec- Control Common Referenced to Negative Input (pin 2)
tion table above for the correct rating. Control Input Current (ON) 0.5 mA
Control Input Current (OFF) -0.5 mA

External Trim MB50xxS-03RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 72.61 32.55 19.20 12.52 8.51 5.84 3.94 2.51 1.39 0.50 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 60.84 27.40 16.25 10.68 7.34 5.11 3.51 2.32 1.39 0.65 k
MB50xxS-05RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 138.88 62.41 36.92 24.18 16.53 11.44 7.79 5.06 2.94 1.24 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 106.87 47.76 28.06 18.21 12.30 8.36 5.55 3.44 1.79 0.48 k
MB50xxS-12RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 413.55 184.55 108.22 70.05 47.15 31.88 20.98 12.80 6.44 1.35 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 351.00 157.50 93.00 60.75 41.40 28.50 19.29 12.37 7.00 2.70 k
An external resister may be added to adjust the converter MB50xxS-15RU
output. Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
To adjust the output UP, connect a 5%, 3W resistor between RDOWN 530.73 238.61 141.24 92.56 63.35 43.87 29.96 19.53 11.41 4.92 k
the minus output pin (5) and the Vout trim pin (6). To adjust
the output DOWN, connect a 5%, 3W resistor between the plus Trim Up
output pin (4) and the Vout trim pin (6). Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 422.77 189.89 112.26 73.44 50.15 34.63 23.54 15.22 8.75 3.58 k
The trim table at right gives suggested resistor values for
this adjustment. MB50xxS-24RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 333.39 148.80 87.26 56.50 38.04 25.73 16.94 10.35 5.22 1.12 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 243.70 108.50 63.43 40.90 27.38 18.37 11.93 7.10 3.34 0.34 k