Page 2 - MPD MB4000RU Datasheet
P. 2



Model Selection Guide www.micropowerdirect.com
Input Output Over Capacitive Fuse
Model Effi ciency Voltage Rating
Load
Number Voltage (VDC) Current (mA) Voltage Current Current (%, Typ) Protection (µF, Max) Slow-Blow
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (VDC Typ) (A)
MB4024S-03RU 24 9.0 - 36.0 1,240 90 3.3 8,000 0 89 3.9 21,000 8.0
MB4024S-05RU 24 9.0 - 36.0 1,850 90 5.0 8,000 0 90 6.2 13,600 8.0
MB4024S-12RU 24 9.0 - 36.0 1,870 95 12.0 3,330 0 89 15.0 2,400 8.0
MB4024S-15RU 24 9.0 - 36.0 1,870 105 15.0 2,670 0 89 18.0 1,500 8.0
MB4024S-24RU 24 9.0 - 36.0 1,835 115 24.0 1,670 0 91 30.0 600 8.0
MB4024D-12RU 24 9.0 - 36.0 1,890 65 ±12.0 ±1,670 ±145 88 ±15.0 ±1,200 8.0
MB4024D-15RU 24 9.0 - 36.0 1,890 65 ±15.0 ±1,330 ±110 88 ±18.0 ±750 8.0
MB4048S-03RU 48 18.0 - 75.0 620 55 3.3 8,000 0 89 3.9 21,000 4.0
MB4048S-05RU 48 18.0 - 75.0 930 55 5.0 8,000 0 90 6.2 13,600 4.0
MB4048S-12RU 48 18.0 - 75.0 930 60 12.0 3,330 0 90 15.0 2,400 4.0
MB4048S-15RU 48 18.0 - 75.0 930 65 15.0 2,670 0 90 18.0 1,500 4.0
MB4048S-24RU 48 18.0 - 75.0 918 75 24.0 1,670 0 91 30.0 600 4.0
MB4048D-12RU 48 18.0 - 75.0 950 45 ±12.0 ±1,670 ±145 88 ±15.0 ±1,200 4.0
MB4048D-15RU 48 18.0 - 75.0 950 45 ±15.0 ±1,330 ±110 88 ±18.0 ±750 4.0
For heatsink option, add suffi x “H” to model number (i.e. MB4024S-15RU-H)
Remote On/Off
Notes:
1. Start up time is measured at nominal input and with a constant resistive load. Applying a signal to pin 3 will turn the unit ON/OFF. If the pin is left open, the unit operates. If
2. Load regulation is specifi ed for a load change of minimum load to full load. grounded, the unit will shut off. The specifi cations for the ON/OFF function are:
3. Cross regulation is measured with the output being tested at 100% load. The second output is varied from 25% to 100% load.
4. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in Parameter Min Typ Max Units
parallel from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output units. Supply On 3.5 12.0 VDC
5. Transient recovery is measured to within a 1% error band for a load step change of 25%. Supply Off 0.0 1.2 VDC
6. Short circuit protection is provided by a “hiccup mode” circuit. Standby Input Current 2.5 mA
7. The switching frequency for 24 VDC output models is 285 kHz. Control Common Referenced to Negative Input (pin 2)
8. Operation at no-load will not damage these units. However, they may not meet all specifi cations if operated below the Control Input Current (ON)
specifi ed minimum load. 0.5 mA
9. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table Control Input Current (OFF) -0.5 mA
above for the correct rating.
External Trim MB40xxS-03RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 72.61 32.55 19.20 12.52 8.51 5.84 3.94 2.51 1.39 0.50 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 60.84 27.40 16.25 10.68 7.34 5.11 3.51 2.32 1.39 0.65 k
MB40xxS-05RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 138.88 62.41 36.92 24.18 16.53 11.44 7.79 5.06 2.94 1.24 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 106.87 47.76 28.06 18.21 12.30 8.36 5.55 3.44 1.79 0.48 k
MB40xxS-12RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 413.55 184.55 108.22 70.05 47.15 31.88 20.98 12.80 6.44 1.35 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 351.00 157.50 93.00 60.75 41.40 28.50 19.29 12.37 7.00 2.70 k
On single output units, an external resister may be added to MB40xxS-15RU
adjust the converter output. Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
To adjust the output UP, connect a 5%, 3W resistor between RDOWN 530.73 238.61 141.24 92.56 63.35 43.87 29.96 19.53 11.41 4.92 k
the minus output pin (5) and the Vout trim pin (6). To adjust
the output DOWN, connect a 5%, 3W resistor between the plus Trim Up
output pin (4) and the Vout trim pin (6). Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 422.77 189.89 112.26 73.44 50.15 34.63 23.54 15.22 8.75 3.58 k
The trim table at right gives suggested resistor values for
this adjustment. MB40xxS-24RU
Trim Down
Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts
RDOWN 333.39 148.80 87.26 56.50 38.04 25.73 16.94 10.35 5.22 1.12 k
Trim Up
Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts
RUP 243.70 108.50 63.43 40.90 27.38 18.37 11.93 7.10 3.34 0.34 k
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com